![red lion 6RLPG-2K Manual Download Page 2](http://html1.mh-extra.com/html/red-lion/6rlpg-2k/6rlpg-2k_manual_1428090002.webp)
2
operation
caution:
do not run the pump Before priming it. the seal and impeller could Be permanently damaged.
a)
preparing the engine:
Follow the engine manufacturer's
instructions before operating.
b)
priming the pump:
Remove the priming plug, fill the casing
with water until full, and replace the plug. if the pump is below
the level of the water that will be pumped (flooded suction), the
pump will automatically fill up when the valves are open.
caution: do not operate this pump dry!
c)
start-up:
Start the pump. In a flooded suction situation, the
pump will discharge the water almost immediately. if the suction
line is above the water level being pumped, it will take a few
minutes to lift the water to the casing and then to discharge it. if
the suction line is quite long, the pump may overheat before the
water in the suction line reaches the pump. in this case, turn the
pump off and drain the casing. Wait a few minutes for the seal
in the pump casing to cool down.
caution:
if the overheated
casing is filled while hot, damage to the seal will occur. Replace
the drain plug and refill the casing with water. Replace the priming
plug and restart the pump.
figure 1
Typical water pump
Discharge
head
Total head
Suction head
25 ft. (8 m) max
figure 2
replacement parts
group
description
components
part number upc code
a
bracket Kit
1,2,3,4
617150
0 10121 14421 7
B
Seal Kit
5,6,7,8,9
617151
0 10121 14422 4
c
impeller Kit
10,11,12,13
617152
0 10121 14423 1
d
Volute
14,15
617153
0 10121 14424 8
e
Check Valve
16
617154
0 10121 14425 5
f
Plug Kit
18,19,21,22
617155
0 10121 14426 2
g
Casing Kit
17,20
617156
0 10121 14427 9
h
base Kit
23,24,25,26
617157
0 10121 14428 6