background image

Before operating or installing 

this pump, read this manual and 

follow all safety warnings and 

operating instructions. 

safety warnings

application

Use this pump for water only, where the vertical suction head from 

the water level is 25 ft. (8m) or less. Head refers to the height of a 

column of water that can be delivered by the discharge of the pump 

(Figure 1). Suction head (or suction lift) is the vertical distance between 

the center of the pump and the surface of the liquid on the suction 

side of the pump. Discharge head is the vertical distance between 

the pump's discharge port and the point of discharge. Total head is 

the sum of the suction head and the discharge head. The elevation 

above sea level and friction losses must be taken into consideration. 

caution:

 

do not operate this pump dry.

 

water is required to 

lubricate pump seal. 

This pump has been tested and operated under 

actual working conditions. Engine, pump, and all accessories were 

found satisfactory. If the pump is not performing as specified, check 

inSTallaTion and TroUblESHooTing sections carefully. 

installation

a)

 

location:

 For permanent installation, put the pump in a clean, 

dry, and ventilated place (Figure 1).

 

Keep the suction line as short as possible. 

This will allow the 

pump to operate at maximum performance and to ensure that 

the casing does not overheat due to the absence of water.

b)

 

mounting:

 Mount the pump on a rigid foundation to eliminate 

creeping due to vibration.

c)

 

suction line:

 Use a suction line the same size as the suction 

on the pump. if the suction pipe is long, increase it by one size 

to improve flow. Slope the suction line upwards to the pump to 

avoid air pockets in the line and hard priming. 

d)

 

suction pipe:

 Use thread compound on all pipe joints. Connec-

tions must be tight, and pipe should be clean and uncorroded.

e)

 

suction hose:

 if the suction line runs generally vertical, use 

an elbow on the hose to prevent kinking. Use double clamps on 

all hose joints. Connections must be tight, and a suction strainer 

is required to filter abrasive material.

note: 

  if you use the pump for dewatering, attach a suction 

screen to the suction line.

note:

   The main cause of pumping problems is a leak in the 

suction line. Even a tiny leak reduces priming and 

pumping greatly.

 WARNING: 

Carefully read the safety messages in this manual 

and on the pump. Keep this manual with the pump at all times.

 

ATTENTION: RENTAl cOmpANIEs ANd pRIvATE 

OWNERs WhO RENT OR lENd ThIs WATER pump TO 
OThERs!

All persons to whom you rent or lend this pump must have access 
to and read this owner's manual. Keep this manual with the pump at 
all times and advise all persons who will operate the pump to read it. 
You must also provide personal instruction on how to safely operate 
the pump, and you must be available to answer any questions that 
the renter or borrower might have.

 WARNING: 

When running, the engine on this pump produces 

carbon monoxide, an odorless, colorless, poison gas. Breathing 
carbon monoxide can cause nausea, fainting, or death.
•  Operate this pump ONLY outdoors. 
•  Keep exhaust gas from entering a confined area through 

windows, doors, ventilation intakes, or other openings. 

998507   rev. 002    7/12

•  Do not operate the pump inside any building, confined area, 

or enclosure such as basements, garages, or similar locations, 
even if doors and windows are open

•  Make sure all connections are tight.
•  Never use with flammable fluids.
•  Turn off engine before servicing.
•  If fuel is spilled, avoid creating any source of ignition until the 

fuel vapors have been cleaned up and removed.

•  Review instructions before operating.
•  Wear ear protection to reduce objectionable noise.

 cAuTION: dO NOT OpERATE ThIs pump dRY!

ENGINE-dRIvEN TRANsFER pump

mOdEls:  6RlpG-2u    6RlpG-2K

Summary of Contents for 6RLPG-2K

Page 1: ...tight and pipe should be clean and uncorroded e Suction Hose If the suction line runs generally vertical use an elbow on the hose to prevent kinking Use double clamps on all hose joints Connections mu...

Page 2: ...it If the suction line is quite long the pump may overheat before the water in the suction line reaches the pump In this case turn the pump off and drain the casing Wait a few minutes for the seal in...

Page 3: ...crease its length or move pump closer to source of liquid Total head is too high for this pump to work against Reduce total head or use a higher head pump Pump will not prime Excessive suction lift 1...

Page 4: ...d maximums as set forth in the instructions Warranty will be VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufacture...

Page 5: ...les raccords Il est recommand d utiliser des tuyaux propres et non corrod s Une cumoire de succion est requise pour filtrer les mat riaux abrasifs e Boyau d aspiration En cas de pompage vertical ajout...

Page 6: ...ue le bo tier se remplisse et se vide par la suite Si la conduite d aspiration est tr s longue la pomppe pourrait surchauffer avant que l eau de la ligne de succion n arrive la pompe Le cas ch ant arr...

Page 7: ...ion V rifier la conduite d aspiration La roue de turbine est obstru e Enlever le bo tier pour le nettoyer La pompe se d samorce Le niveau de liquide est inf rieur l extr mit de la conduite d aspiratio...

Page 8: ...tion au del des maximums recommand s comme il est indiqu dans les instructions La garantie est NULLE si l une des conditions suivantes s applique 1 Le produit est utilis pour des applications autres q...

Page 9: ...recomienda se utilice tuber as limpias y sin corrosi n e Manguera de succi n Si la l nea de succi n est b sica mente vertical utilice un codo en la manguera para evitar que se doble Utilice abrazadera...

Page 10: ...rgarla Si la l nea de succi n es muy larga la bombapodr recalenstarsedebidoaqueelaguadentrodelaca er a de succi n est alcanzando la bomba En este caso apague la bomba y drene el cuerpo de la bomba Esp...

Page 11: ...ba a Limpie las l neas y los acoplamientos b Aseg rese que las v lvulas est n funcionando bien c Aumente el tama o de la tuber a manguera para reducir la p rdida por fricci n El extremo de la l nea de...

Page 12: ...asan los valores m ximos recomendados estipulados en estas instrucciones Esta garant a quedar ANULADA si se hallan cualesquiera de las siguientes condiciones 1 El producto se utiliza para prop sitos d...