![red lighting Classe BS 2 User Manual Download Page 11](http://html1.mh-extra.com/html/red-lighting/classe-bs-2/classe-bs-2_user-manual_1427688011.webp)
Classe BS2 v1.0
10
Address 1 Address 14 Address 27
6. DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an electrically noisy
environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in
preventing corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3,which is then plugged
into the output XLR socket of the last fixture in the chain. Please see illustrations below.
7. Projector DMX start address selection
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct
fixture responds to the correct control signals. This digital starting address is the channel number
from which the fixture starts to “listen” to the digital control information sent out from the DMX
controller. The allocation of this starting address is achieved by setting the correct number on the
display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different
address for each fixture individually.
If you set the same address, all the units will start to “listen” to the same control signal from the
same channel number. In other words, changing the settings of one channel will affect all the
fixtures simultaneously.
Summary of Contents for Classe BS 2
Page 1: ......