A-5
INSTALLATION
FX360XL
InTernal COnTrOls
The User Interface pc board has one bank of dip switches. As
shipped from the factory and under normal conditions, the dip
switches are all in the ‘off’ position. There are 3 instances that
require a change of the dip switch.
Factory Default Setting
- All Switches in the ‘OFF’ Position
Test Mode Setting
1. Enter a test mode.
This is utilized when the machine is
connected to a grid load for servicing
a.
Turn switch #4 to the ‘ON’ position.
- Switch #4 in the ‘ON’ Position
VRD Enabled Setting
2. Enter VRD Mode
(VRD Enabled)
a.
Turn switch #5 to the ‘ON’ Position
- Switch #5 in the ‘ON’ Position
Calibration
3. Enter Calibration Mode.
This allows the machine voltage
and current to be calibrated while connected to a grid load
a.
Turn switch #1 to the “ON” Position
- Switch #1 in the ‘ON’ Position
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
FIGURE A.3 - DIP SWITCH LOCATION ON USER INTERFACE PCB