Control module STM 22 RED/DUO 

6

 

B6_Control_SYS20_EN_V1.3.doc

 

Art. Nr. 102-020401135 

30 / 36 

6. 

Control module STM 22 RED/DUO 

6.1. 

Controls on STM 22 RED/DUO 

The control module STM 22 RED/DUO works with an active HIGH level. To activate the function 
+24V must be present. Safety inputs will be activated by an interruption. The basic signal 0V is 
connected to the protective earth. This compound could be separated with ground screw for test-
ing – LED1 (red) light. 

 

Control module and power supply 

 

 

 

 

 

ELECTRIC SHOCK

 

  Electrical shock, burns, death if you touch the power supply without protective 

cover. 

  Before removing the metal cover disconnect the drive from the main.  

  Installation only reconnects to the network after the protection cover is 

closed.  

 

 

 

 

Control module STM 22 

RED/DUO

Power supply 

and mains fuse 

DANGER 

Summary of Contents for STM 20 RED/DUO

Page 1: ...Control Sliding door system 20 Copyright agtatec AG 2011 Manufacturer Service Hotline Distributer agtatec ag Allmendstrasse 24 CH 8320 Fehraltorf Art Nr 102 020401135 ...

Page 2: ...ate STM 20 RED DUO 13 3 4 Wiring diagram control module STM 20 RED DUO 16 3 5 Components RED DUO system 18 3 5 1 Overview of the additional components 18 4 Control module STM 21 19 4 1 Controlling elements on STM 21 19 4 2 Application field of control module STM 21 20 4 2 1 Typical range of applications 20 4 2 2 Unavailable applications 20 4 3 Type plate STM 21 20 4 4 Wiring diagram control module...

Page 3: ...pplications 31 6 2 1 Escape and rescue routes as RED installation 31 6 2 2 Heavy door leafs as DUO installation 31 6 3 Type plate STM 22 RED DUO 31 6 4 Wiring diagram control module STM 22 DUO RED 34 6 5 Components RED DUO installations 36 6 5 1 Overview of the additional components 36 ...

Page 4: ...M 21 RED 24 Controls on STM 22 RED DUO 30 D Document identification 5 E Escape and rescue routes as RED installation 13 25 31 G General 5 H Heavy door leafs as DUO installation 13 31 I Instruction manual 6 O Overview of each chapter 5 Overview of the additional components 18 29 36 S Structure of the documentation 5 T Type plate STM 20 8 Type plate STM 20 RED DUO 13 Type plate STM 21 20 Type plate ...

Page 5: ... B7_Commissioning B8_Annex B9_Assembly and Start Up FTA FBO 1 2 1 Overview of each chapter Chapter Content B1_General General Safety instructions Preparations Technical data General plans B2_Assembly STA General Installation drive module D STA E STA Installing running gear D STA E STA Installing door leale D STA E STA Installation of the drive unit D STA E STA B3_Assembly TSA General Floor tracks ...

Page 6: ... STM 20 RED DUO Control module STM 21 Control module STM 21 RED Control module STM 22 RED DUO B7_Commissioning General Principles for commissioning The CAN bus BDE D Operating unit Operating instructions Easy Programmer EPC 903 Start Up Commissioning of systems Parameter explanations B8_Annex General Module types cladding height 200 mm Drive module Drawings Article list B9_Assembly and Start Up FT...

Page 7: ...e interrupted for test reasons by use of the ground screw located next to terminal 12 LED 2 red comes on Control module and power supply ELECTRIC SHOCK Electric shock combustion death when touching the power supply without protection cover Before opening the metallic cover of the power supply unit disconnect it from the mains The installation may only be connected to the mains again after the prot...

Page 8: ...lave only in case of two STM Light emitting diode Meaning LD1 Red control LED For MF button S1 blinking when button is pressed LD2 Ground Red control LED Must light up if protective earth screw is withdrawn Otherwise grounding is on LD3 green 24 V Is on if 24 volt circuit is OK Comes off in case of short circuit in 24 volt LD4 green 32 V Is on if system connected to mains voltage Multifunctional k...

Page 9: ...UT OUTPUT parameter Emergency Stop with Reset is active 14 pulses Hardware Reset will be done after approx 12 sec Connector designation Connections J1 Mains plug J2 Terminals 25 28 for BDE D J3 Terminals 1 12 Functions according to wiring diagram 102 020109934 J4 Locking device J5 Battery J6 Motor brake J7 ATE motor J8 CAN bus J9 CAN bus plug for FPC servicing J10 Encoder motor J11 Extra printed c...

Page 10: ...Control module STM 20 2 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 10 36 2 3 Wiring diagram control module STM 20 102 020109935 ...

Page 11: ...Control module STM 20 2 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 11 36 102 020109935 ...

Page 12: ...reasons by use of the ground screw located next to terminal 12 LED 1 red comes on Control module and power supply ELEKTRIC SHOCK Electric shock combustion death when touching the power supply without protection cover Before opening the metallic cover of the power supply unit disconnect it from the mains The installation may only be connected to the mains again after the protec tion cover has been ...

Page 13: ... tested according EN 13849 1 2006 category 2 PLc STM 20 RED DUO is usually delivered with a RED software In the event of applications as DUO operators heavy doors the appropriate DUO software must be installed on CPU 1 and CPU 2 FPC flash manual installation both CPU s 3 3 Type plate STM 20 RED DUO STM 20 RED DUO Jumper Change of function JP1 Jumper on HEA Allows emergency stop and HEA to be conne...

Page 14: ... pulses Calibrating door parameters 4 pulses Entering programming level 5 pulses RED Redundancy test if system connected to mains voltage DUO Battery emergency reaction as long as system discon nected from mains Battery test in case of mains connection 8 pulses Loads default values of door type selected 9 pulses Back to factory settings afterwards emergency stop must be actuated within 10 seconds ...

Page 15: ...FPC servicing J14 Reserved for future modules J15 Encoder motor 1 J16 Encoder motor 2 not necessary for DUO applications J17 Reserved for future modules J18 Reserved for future modules Emergency stop Cuts the motor off the amplifier Door can be moved manually Only for DUO applications Inapplicable for RED applications Emergency open Opens the door if not locked Only for RED applications NOTE NOTE ...

Page 16: ...Control module STM 20 RED DUO 3 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 16 36 3 4 Wiring diagram control module STM 20 RED DUO 102 020110534 ...

Page 17: ...Control module STM 20 RED DUO 3 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 17 36 102 020110534 ...

Page 18: ...escue routes On a RED installation there is a special RED software for CPU1 and CPU2 loaded on the control module STM 20 RED DUO This software complies with the standard EN 13849 1 2006 Category 3 PLd On RED system the Encoder cable must be also connected on the 2nd Motor 3 5 1 Overview of the additional components Basically the components will mounted and wired analogue to a normal sliding door B...

Page 19: ...nterrupted for test reasons by use of the ground screw located next to terminal 12 LED 2 red comes on Control module and power supply ELECTRIC SHOCK Electric shock combustion death if touching the power supply without protec tion cover Before opening the metallic cover of the power supply unit disconnect it from the mains The installation may only be connected to the mains again after the protec t...

Page 20: ...e applications The following applications are not available with control module STM 21 No RED installation redundant for escape and rescue routes No DUO installation heavy doors No TOS installation sliding swivelling doors No MPV multipoint locking device No FEM1 application interlock function 4 3 Type plate STM 21 STM 21 DUO Jumper Change of function JP1 Jumper on HEA Allows emergency stop and HE...

Page 21: ...tering programming level 5 pulses Battery emergency reaction as long as system is dis connected from mains Battery test in case of mains connection 8 pulses Loads default values of door type selected 9 pulses Back to factory settings afterwards an emergency stop or a reset must be actuated within 10 seconds The function emergency stop with reset can only be actuated if the INPUT OUTPUT parameter E...

Page 22: ...Control module STM 21 4 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 22 36 4 4 Wiring diagram control module STM 21 102 021110650 ...

Page 23: ...Control module STM 21 4 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 23 36 102 021110650 ...

Page 24: ... terminal 12 LED 1 red comes on Control module and power supply ELEKTRIC SHOCK Electric shock combustion death when touching the power supply without protection cover Before opening the metallic cover of the power supply unit disconnect it from the mains The installation may only be connected to the mains again after the protec tion cover has been closed again 5 2 Applications Control module STM 2...

Page 25: ...oned internal Not visible required for VRR2 MPV 16 JP4 On RED and DUO installation D ST EST R Factory setting EST L Fixing connecting clamp to upper part of toothed belt Shunt position remains unchanged JP5 Standard Master opera tion mode Slave only in case of two STM Light emitting diodes Meaning LD1 Ground red control LED Ground must light up if protective earth screw is with drawn Otherwise gro...

Page 26: ...y stop must be actuated within 10 seconds 14 pulses Hardware reset is performed after approx 12 seconds Connector designation Connections J1 Terminals 25 28 for BDE D J2 Terminals 1 12 Functions according to wiring diagram 102 020110534 J3 Terminals 13 17 only used with RED applications Functions according to wiring diagram 102 020110534 J4 Battery 1 used for DUO and RED applications J5 Battery 2 ...

Page 27: ...Control module STM 21 RED 5 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 27 36 5 4 Wiring diagram control module STM 21 RED 102 020110534 Control module 21 RED ...

Page 28: ...Control module STM 21 RED 5 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 28 36 102 020110534 Control module 21 RED ...

Page 29: ...scape and rescue routes On a RED installation there is a special RED software for CPU1 and CPU2 loaded on the control module STM 21 RED This software complies with the standard EN 13849 1 2006 Category 3 PLd On RED system the Encoder cable must be also connected on the 2nd Motor 5 5 1 Overview of the additional components Basically the components will be mounted and wired analogue to a normal slid...

Page 30: ...y an interruption The basic signal 0V is connected to the protective earth This compound could be separated with ground screw for test ing LED1 red light Control module and power supply ELECTRIC SHOCK Electrical shock burns death if you touch the power supply without protective cover Before removing the metal cover disconnect the drive from the main Installation only reconnects to the network afte...

Page 31: ...2 RED DUO control module with RED Software complies with EN 13849 1 2006 Category 3 PLd 6 2 2 Heavy door leafs as DUO installation The STM 22 RED DUO control module with RED Software complies with EN 13849 1 2006 Category 2 PLc The STM 22 RED DUO is usually delivered with RED soft ware For applications as DUO drive heavy doors the corresponding DUO software on CPU1 and CPU2 need to be installed FP...

Page 32: ...s pressed Multi function key Function after impulses have been given 1 puls Triggering the opening movement AKI 2 pulses Calibrating ELS 3 pulses Calibrating door parameters 4 pulses Entering programming level 5 pulses RED Redundancy test with existing mains power DUO Battery emergency reaction if no mains power available Battery test with existing mains power 8 pulses Loads default values of door...

Page 33: ...rcuit board ELS ZLP ELS J12 Additional printed circuit board AKI ZLP AKI J13 CAN Bus service plug for FPC J14 Reserved for future modules J15 Encoder Motor 1 J16 Encoder motor 2 not necessary for DUO applications J17 Reserved for future modules J18 Reserved for future modules Emergency stop Cuts the motor off the amplifier Door can be moved manually Only for DUO applications Inapplicable for RED a...

Page 34: ...Control module STM 22 RED DUO 6 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 34 36 6 4 Wiring diagram control module STM 22 DUO RED 102 020110534 ...

Page 35: ...Control module STM 22 RED DUO 6 B6_Control_SYS20_EN_V1 3 doc Art Nr 102 020401135 35 36 102 020110534 ...

Page 36: ...s On a RED installation a special RED software for CPU1 and CPU2 is installed on the control module STM 22 RED DUO This software complies with the stan dards EN 13849 1 2006 Category 3 PLd On RED system the Encoder cable must be also connected on the 2 Motor 6 5 1 Overview of the additional components Basically the components will be mounted and wired analogue to a normal sliding door Below we ref...