4
Specifications
16 / 30
BAL_PROTECT_RC2_RC3_EN_1V0_BLA_121-006454704
4
Specifications
4.1
Dimensions of the system
Dimensions
Minimum
Maximum
F = Total width
2199 mm
5655 mm
A = Width of passage
733 mm
2582 mm
G = Height of passage
2200 mm
3000 mm
I = Canopyn- / Cladding-height
220 mm
On request
T = Total depth
297 mm
297 mm
4.2
Electrical specifications of the system
Mains voltage:
100-240V AC (STA 20) / 115V AC (Serie 5100)
Frequency:
50-60 Hz
Mains fuse:
16A circuit breaker with tripping characteristic C or K
Power consumption:
max.: 700 VA
Control voltage:
24V DC (extra low voltage)
Fuse in the control:
T4A (depending on the door control)
Safety class:
1
Degree of protection:
IP 20
4.3
Environmental conditions
Temperature range
From -15 to +50° C
Humidity range
Up to 85% rel. humidity, not condensing