Description
3
BAL_PROTECT_RC2_RC3_EN_1V0_BLA_121-006454704
13 / 30
Floor rail
1 - Floor profile left
3 - Floor profile right
2 - Sub-construction
3.2
Safety features and controls
3.2.1
Control elements
Standard control elements
Optional Control elements
BDE-D
BDE-M
Key-operated switch
3.2.2
Opening and security sensors (combined)
Each passage area is monitored with opening and security sensors. If an opening or security sensor
is activated during the closing process while in
AUTOMATIC
or
ONEWAY TRAFFIC
operating mode,
then the respective sliding door will re-open/reverse again.
NOTICE
The opening sensors located in the direction of the escape route ( (generally inside) must be
set to cover the entire passage width to the depth at a depth of 1500mm and be self-monitor-
ing.
3.2.3
Collision detection
If a door wing hits an obstacle during the closing process, then the door will stop immediately and re-
open.
Equally, the door wing will stop immediately if the door hits an obstacle during the opening process.
The opening process will start anew after 3 seconds at extra slow speed.
3.2.4
Security sensors in the passage area
Each passage area is monitored with its own security sensor. I a security sensor is activated during
the closing process in the AUTOMATIC or ONEWAY TRAFFIC operating mode, then the respective
sliding door will re-open/reverse.