7
Inspection and maintenance
34 / 48
BAL_K32_K42_ST_EN_1V2_REC_121-006454613
Task
Personnel
When?
Entered in test log
book?
Function and safety check
System operator
Monthly
No
Tasks of qualified person
Task
Personnel
When?
Entered in test log
book?
Acceptance test
Qualified person
After assembly of the door system
ready for operation
Yes
Servicing
Qualified person
1 x annually, or according to country-
specific standards and guidelines
Yes
Test (inspection)
Qualified person
1 x annually, or according to country-
specific standards and guidelines
Yes
Test (inspection) for door
systems in escape routes
Qualified person
2 x annually, or according to country-
specific standards and guidelines
Yes
Testing of fire doors
Qualified person
1 x annually, or according to country-
specific standards and guidelines
Yes
7.3
Monthly inspection work performed by the operator
The monthly tests and inspections of individual components by the operator require little time and
serve in particular to prevent accidents caused by improper handling of the system. Depending on the
equipment of the plant, we recommend that the following inspection work be carried out on a monthly
basis.
Item Nr.:
Test / Control
Procedure
Expected result
1
Function test
motion detectors
– Select the AUTOMATIC operating
mode.
– When the turnstile comes to a
standstill, enter into the detection
area of the motion detector.
– Conduct this test from the interior
and exterior.
– The turnstile must start to rotate in
time.
6,
9,
16
Visual inspection of all
safety strips
– Select the MANUAL operating
mode.
– Visually inspect all safety strips.
– The safety strips must not have
any mechanical damage and they
must be installed correctly and
firmly over the entire length.
22
possibly
on the ex-
terior
Function test
BDE-V key switch
– Start the turnstile rotating in
AUTOMATIC or CONTINUOUS
mode.
– Turn the key switch to the right to
LOCKED.
– Turn the key switch to the left to
UNLOCKED.
– The turnstile rotates to the locked
position and locks.
– The turnstile unlocks and goes
back to AUTOMATIC mode.
23
possibly
on the ex-
terior
Function test key emer-
gency switch
– Start the turnstile rotating in
AUTOMATIC or CONTINUOUS
mode.
– Turn the key emergency switch to
the left or right for approx. 5
seconds.
– The turnstile rotates at slow speed
in the predefined direction of rota-
tion.
– When the key emergency switch is
released the turnstile will stop im-
mediately! The operating mode
can be changed wit the BDE-D-
KTA.