Malfunctions
8
BAL_K32_K42_ST_EN_1V2_REC_121-006454613
39 / 48
107
Start button 1 Stator
(TA-SRT1_S)
– Door rotates permanently
– Check push button
– Perform reset
– If not successful, contact service
TA-SRT1 Stator active
108
Start button 2 Stator
(TA-SRT2_S)
– Door rotates permanently
– Check push button
– Perform reset
– If not successful, contact service
TA-SRT2 Stator active
109
Vertical sensor stator in-
side (OP-VSSI)
– OptoStop, OptoSlow, de-
pending on the adjusted
sensor function stop the rota-
tion or reduce the rotation
speed in the active range of
the sensor
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSSI active
110
External vertical sensor
stator (OP-VSSA)
– OptoStop, OptoSlow, de-
pending on the adjusted
sensor function stop the rota-
tion or reduce the rotation
speed in the active range of
the sensor
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSSA active
111
Vertical sensor rotor
blade 1 (OP-VSR1)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR1 active
112
Vertical sensor rotor
blade 2 (OP-VSR2)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR2 active
113
Vertical sensor rotor
blade 3 (OP-VSR3)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR3 active
114
Vertical sensor rotor
blade 4 (OP-VSR4)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
VSR4 active
115
Safety edge inside drum
edge (SL-TRKI)
– SafetyStop, Immediate stop
of the rotation
– Remove object from safety edge, possibly
dirt on the floor, under a heel guard
– Perform reset
– If not successful, contact service
SL-TRKI active