HandKey II Installation and Operation Manual
Revision 2.0
Page 33
Figure 3-10: Printer to HandKey II Wiring Diagram
Setting the DIP Switches
DIP Switch settings perform three tasks for the Hand Reader (see Figure 3-11).
•
Set End of Line (EOL) Termination to match the type of termination the network
being used needs.
•
Set the Communication Method to match the type of network used.
•
Erase Memory to clear Hand Reader memory to all factory default values and also
clear all user memory.
Refer to Figure 3-11 for the location of all DIP switches described in this section.
If a Hand Reader is used as a stand-alone Hand Reader, the End of Line (EOL)
Termination and Communication Method dip switches are not used and should be left
in their default positions.
26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
4-Wire
RS-485
Connection
12 to 24 V
AC/DC
Input
+
-
* These components are not supplied by Recognition Systems, Inc.
TOP OF THE
HAND READER
HINGE
WALL TO WHICH
THE HAND READER
IS ATTACHED
TS-1
TS-2
TS-3
J4
RJ-45 Jack
*Serial Printer
RJ-45
Connector
RJ-45
Connector
RJ-45 to Printer
Adapter
(if required)
NOTE