浙江热刺激光技术有限公司
Zhejiang Reci Laser Technology Co., Ltd.
- 15 -
Chapter 5 Operating Instruction
5.1 Button Description
Figure 11 Button Description
There are four buttons on the laser, including Up, Down, Back, OK. Up and Down is for adjusting the parameters. Back is
for returning to the previous step. OK is for authorizing the change or switch on the laser while hand-testing.
5.2 Specific details for operation
5.2.1 Cancel Time Operation
(1)
Press the OK button to enter the password setting, then P0000 will be shown on the display. Here the
Back button is used to select the digit. It is noted that the currently changed digit will be brighter than the
others.
(2)
Press the Up and Down buttons to modify the value.
(3)
After modifying, press the OK button and 0 will be shown on the display to prove the correct inputting.
Then press the OK button to enter the standby state.
(4)
The time limit will be cancelled after restarting the laser. And it will be used indefinitely. (The laser will
be locked due to repeatedly entering the wrong password after a certain number of times.)
5.2.2 Laser Testing State
(1)
Press the OK button to enter the password setting, then P0000 will be shown on the display. Here the
back button is used to select the digit. It is noted that the currently changed digit will be brighter than the
others.
(2)
Press the Up and Down buttons to modify the value to 1,000.
(3)
After pressing the OK Button, F-000 will be shown on the display for frequency setting. The frequency
range can be adjusted from 0 to 100. (For example, F-10 means the frequency of PWM is 10 kHz.)
(4)
P-xxx will be shown on the display for duty cycle setting after pressing the OK button. The duty cycle
range is 0~52%. (For example, P-10 means the duty cycle of PWM is 10%)
(5)
The laser testing state will be ready after pressing the OK button. Then press it again for laser on and
release it for laser off. 8888 will be shown after long pressing the Back button for returning successfully.
Note: In the testing state, the laser cannot be controlled by the PWM and the enable directly. The testing
state can be cancelled after long press the Back button more than 5 seconds and 8888 will be appeared on
the display to prove returning successfully.