浙江热刺激光技术有限公司
Zhejiang Reci Laser Technology Co., Ltd.
- 16 -
5.3 Normal Problem
5.3.1 Wrong Password
If failing to enter the password interface after pressing the OK button. This is because the wrong password
has been inputted too many times, which causes inputting function locked. It will be available after one hour.
5.3.2 No laser beam after pressing the OK button.
(1)
The button may be damaged due to pressing by the nail for long time. So, it is recommended to press it
with fingertips.
(2)
Pressing time is too short to trigger the switch. In this way, long press the OK button in the testing state 2
till the numbers on the display disappeared.
Error Code
Descriptions
E 2
The machine temperature is too high.
E 3
Interlocked and disconnected.
E 4
Voltage error caused by power supply (Less than
48V or More than 52V)
E 5
Condensations
E 6
Over-reflection
E 7
Laser Pre-detection Fault (Please turn off the power
and restarting. If it is invalid repeatedly, please
contact us. )
E 8
Trial Time Expires
Table 11 Error Code
5.3.3 Password Input for Trial Time
(1)
Press the OK button to enter the password setting, then P0000 is shown on the display. Press the Back
button to select the digit to be changed. The currently changed number will be brighter than the others.
(2)
Select the digits which needs to be changed, then press UP or Down button to modify the value to 3000.
(3)
After pressing the OK button, H-6 is shown on the display, which means the unlock time. Users can
press UP or Down to change the unlocking time. H-6, H-12 and H-18 means separately unlocking time
can be 6 months, 12 months and 18 months.
(4)
After pressing the OK button, F0000 is shown on the display. Please contact us to get the respective
password for extending the usage time. If the password for 18 months, the laser will be no time limit. If
the password for 6 months, then users need to get a new one when the alert will be pop-on after 6 months
using. If the password is wrong, E-8 will be shown on the display. The password will be successful when
8888 is appearing on the display before restart.