background image

 

REBOTEC / 

BA-Nr.: 02.07.142/2021-12-A01

 

- 8 - 

EN 

 

 

 

 

 

 

 

11.5  Removing the footrests 

  Remove or fold up the seat. Then, raise the foot-

rest by approx. 100 mm and turn outwards by 90 
degrees. 

  Now you can push the footrest all the way up and 

pull it out 

11.6  Handling of the toilet bucket 

  From the back of the chair, slide the toilet bucket 

under the seat. To remove, slightly lift the bucket 
and then pull it out backwards. 

  In the version with a 2-section toilet seat, you can 

alternatively insert or remove the toilet bucket from 
above by lifting the seat. 

11.7  Removing the backrest cushion 

 For cleaning purposes or for 

replacement 

the 

backrest 

cushion can be removed from 
the  arresting  grid  at  the 
backrest of the chair by press-
ing  against  it  with  your  hand 
from the back. 

12  Troubleshooting 

Fault 

Potential cause 

Remedy 

Armrest can-
not be swiv-
elled down 

Deposits in the 
locking device 
(locking bolt) 

Cleaning, 
checking 
regularly 

Locking bolt 
cannot be 
pulled out 

Deposits, tension 
spring jammed or 
defective 

Cleaning, 
Replace 
the locking 
bolt 

Footrest can-
not be folded 
down 

Deposits in the 
joint, 
Bracing 

Cleaning, 
Check 
screw con-
nection 

Wheel lock 
does not brake 

General defect 

see mainte-
nance! 

Turning the 
wheel is stiff 

Deposits 

Cleaning 

Wheel does 
not turn 

General defect 

see mainte-
nance! 

Fault 

Potential cause 

Remedy 

Uneven run-
ning of the 
wheel 

Severe uneven 
tread wear 

see mainte-
nance! 

Chair frame 
too unstable 

Screw connections 
too loose 

Screw con-
nections: 
Tighten 
frame, 
wheel in-
serts 

Wheel insert 
bent/distorted 

Hitting an obstacle 

see mainte-
nance! 

13  Care and maintenance 

13.1  Cleaning and care 

The  product  can  be  cleaned  using  a  mild 

conventional  cleaning  and  disinfecting 

agent. After cleaning, wipe the product with a clean, 
moist cloth and then wipe it dry with a dry cloth. 

  Do  not  use  scouring  agents  or  cleaning  agents 

with  aggressive  ingredients  (acids,  thinners),  as 
well as hard cleaning objects (brushes), as other-
wise  the  surfaces  may  be  damaged  or  deposits 
may form on the materials. 

Keep  the  product  clean  and  clean  it  regu-
larly. Special attention must be paid to hy-
giene in the sensitive areas. 

 

  The  product  is  suitable  for  manual  cleaning  and 

disinfection.  Please  observe  the  reprocessing  in-
structions (02.12.156). 

13.2  Maintenance 

  Wear and tear that is not recognised in time and/or 

improper  handling,  as  well  as  irregular  or  no 
maintenance may result in accidents. 

For safety reasons, the product must be pro-
fessionally maintained at least once a year

  Check product for visible damage 

  (Cracks, breakage, loose parts) 

  Check stability before use 

Maintenance/inspection scope 

  Maintenance should include the following in-

spection work and should be documented. 

  All  bolted  connections  for  tightness  (espe-

cially the wheel inserts and the frame) 

  Function of the armrests and locking bolts 

  Function  of  the  footrest  (replace  defective 

footrests) 

  Running  characteristics  and  tread  of  the 

wheels (replace defective wheels) 

Summary of Contents for 357.10 Series

Page 1: ...6 66 Web www rebotec de BA Nr 02 07 142 2021 12 A01 Email info rebotec de Read this User Manual before using the device for the first time and keep it at hand for the user as well as for future use an...

Page 2: ...cope of delivery 6 9 Setting up for use 6 9 1 Folding down the footrests 6 9 2 Adjusting the footrest height 6 9 3 Assembling the backrest 6 10 Product data 6 11 Operation of the product 6 11 1 Sittin...

Page 3: ...ust be present during use The product is not in tended for prolonged sitting and transfer Specification Maximum user weight 90 kg Height adjustable footrests Wheelchair 4 swivel castors lockable Indoo...

Page 4: ...parts and processing complaints the device name serial number and year of manufacture will be required Symbol Meaning Symbol Meaning Read the manual Year of manufac ture of De vice Serial num ber Imp...

Page 5: ...ators hot wa ter Allow the product to cool down before use If the product is used by patients with in sensitive skin no temperature perception or skin damage a heat check e g touching with the back of...

Page 6: ...the armrest backwards place the backrest on the tubes of the chair frame and push it onto the base frame as far as it will go Swivel the armrests forwards again so that they engage in the groove on t...

Page 7: ...he patient must support themselves with their arms on the armrests and slowly rise from the seat Do not lean your body too far forward to avoid a potential risk of falling The patient should be helped...

Page 8: ...ear see mainte nance Chair frame too unstable Screw connections too loose Screw con nections Tighten frame wheel in serts Wheel insert bent distorted Hitting an obstacle see mainte nance 13 Care and m...

Page 9: ...ese will only adversely affect the safety and functioning of the chair Only use OEM spare parts by the manufac turer REBOTEC for repairs Observe all guar antee and warranty information After maintenan...

Page 10: ...UR shower seat padding 5 450 10 05 Armrest engagement lock complete 6a 447 XX 57 Footrest complete left 6b 447 XX 59 Footrest complete right 7 445 10 20 PUR backrest cushion 02 07 142 User Manual 02 1...

Page 11: ...0 E Seat width 400 F Seat depth 450 G1 Slide over height 410 G2 Slide over width 330 H Knee height of footrest max 380 540 I Armrest height 765 J1 Front castor diameter 125 J2 Rear castor diameter 125...

Page 12: ...OTEC BA Nr 02 07 142 2021 12 A01 12 EN REBOTEC Rehabilitationsmittel GmbH D 49610 Quakenbr ck Artlandstr 57 59 Telephone 49 0 5431 9416 0 Fax 49 0 5431 9416 66 Web www rebotec de Email info rebotec de...

Reviews: