8  Scope of delivery 

  1x shower / toilet wheelchair 

  1x toilet bucket 

  1x user manual (02.07.142) 

  The  reprocessing  and  maintenance  instructions 

can  be  ordered  or  viewed  and  downloaded  at 

www.rebotec.de/downloads

. 

9  Setting up for use 

  The  product  has  been  carefully  inspected  in  the 

factory  for  freedom  from  defects  and  complete-
ness.  Please  check  the  product  for  any  possible 
damage which may have occurred during transport 
and for completeness of the scope of delivery upon 
receipt.  Assembly  or  adjustment  shall  be  carried 
out by the specialist dealer 

9.1  Folding down the footrests 

  Turn  (1)  the  footrests  forwards  until  they  engage 

automatically. Fold (2) the  footrests down. Adjust 
the height of the footrests if necessary. 

 

9.2  Adjusting the footrest height 

  The footrest height can be adjusted in 7 positions. 

Loosen and remove the screws on the side of the 
footrest using an Allen key (SW 5). Select the ap-
propriate height level (1-7) and screw the footrest 
back in place. Make sure that the screws are firmly 
tightened! 

 

9.3  Assembling the backrest 

 

Swivel  the  armrest 

backwards, 

place 

the 

backrest on the tubes of the 
chair frame and push it onto 
the  base  frame  as  far  as  it 
will go. 

  Swivel  the  armrests  forwards  again  so  that  they 

engage in the groove on the backrest and with the 
locking bolt in the base frame. 

10  Product data 

  We  reserve  the  right  to  make  technical  develop-

ments  and  improvements  with  respect  to  the  de-
sign shown in this User Manual. 

  See 15 

Characteristic 

Value 

Bremen

 

1. 

User weight 

max. 90 kg 

2. 

Product weight* 

16.4 kg 

3. 

Total weight* 

19.0 kg 

Skin compatibility 

DIN EN 10993-1/-5 

*Without accessories 

11  Operation of the product 

  Before use, it must be ensured that the product is 

in proper condition. If defects or malfunctions are 
evident,  the  product  must  not  be  used.  Have  the 
defects corrected by a specialist dealer before use. 

If  necessary,  depending  on  the  patient's 
limitations  (adequate  mobility  and  muscle 
strength), sitting down and getting up

 

must 

be done with the help of a caregiver. Subsequent 
adjustments  may  only  be  made  by  qualified  per-
sonnel. 

11.1  Sitting down 

  Before  sitting  down  and  standing  up,  make  sure 

that the product is securely positioned to prevent it 
from  slipping  or  tipping  over,  that  at  least  two 
wheels are braked, that the armrests are properly 
engaged, that the seat surfaces are firmly in place, 
and that the footrests are folded to the side or up. 

Max 

Min 

Summary of Contents for 357.10 Series

Page 1: ...6 66 Web www rebotec de BA Nr 02 07 142 2021 12 A01 Email info rebotec de Read this User Manual before using the device for the first time and keep it at hand for the user as well as for future use an...

Page 2: ...cope of delivery 6 9 Setting up for use 6 9 1 Folding down the footrests 6 9 2 Adjusting the footrest height 6 9 3 Assembling the backrest 6 10 Product data 6 11 Operation of the product 6 11 1 Sittin...

Page 3: ...ust be present during use The product is not in tended for prolonged sitting and transfer Specification Maximum user weight 90 kg Height adjustable footrests Wheelchair 4 swivel castors lockable Indoo...

Page 4: ...parts and processing complaints the device name serial number and year of manufacture will be required Symbol Meaning Symbol Meaning Read the manual Year of manufac ture of De vice Serial num ber Imp...

Page 5: ...ators hot wa ter Allow the product to cool down before use If the product is used by patients with in sensitive skin no temperature perception or skin damage a heat check e g touching with the back of...

Page 6: ...the armrest backwards place the backrest on the tubes of the chair frame and push it onto the base frame as far as it will go Swivel the armrests forwards again so that they engage in the groove on t...

Page 7: ...he patient must support themselves with their arms on the armrests and slowly rise from the seat Do not lean your body too far forward to avoid a potential risk of falling The patient should be helped...

Page 8: ...ear see mainte nance Chair frame too unstable Screw connections too loose Screw con nections Tighten frame wheel in serts Wheel insert bent distorted Hitting an obstacle see mainte nance 13 Care and m...

Page 9: ...ese will only adversely affect the safety and functioning of the chair Only use OEM spare parts by the manufac turer REBOTEC for repairs Observe all guar antee and warranty information After maintenan...

Page 10: ...UR shower seat padding 5 450 10 05 Armrest engagement lock complete 6a 447 XX 57 Footrest complete left 6b 447 XX 59 Footrest complete right 7 445 10 20 PUR backrest cushion 02 07 142 User Manual 02 1...

Page 11: ...0 E Seat width 400 F Seat depth 450 G1 Slide over height 410 G2 Slide over width 330 H Knee height of footrest max 380 540 I Armrest height 765 J1 Front castor diameter 125 J2 Rear castor diameter 125...

Page 12: ...OTEC BA Nr 02 07 142 2021 12 A01 12 EN REBOTEC Rehabilitationsmittel GmbH D 49610 Quakenbr ck Artlandstr 57 59 Telephone 49 0 5431 9416 0 Fax 49 0 5431 9416 66 Web www rebotec de Email info rebotec de...

Reviews: