14
LIGHTING INSTRUCTIONS
1.
Read and understand all operating instructions before lighting
Ensure that all protective fi lm has been removed from stainless
burn tray prior to lighting.
2.
Burner control knob must be in the OFF position.
3.
Connect propane (LP) cylinder (see previous pages).
4.
Slowly open valve on LP gas cylinder.
5.
Push and hold ignitor button to create sparks.
6.
While holding the ignitor button with one hand, use your other
hand to push and turn the control knob to the LIGHT position
to light the burner.
7.
Keep Burner Control Knob pressed in for 15-30 seconds after
ignition.
8.
If ignition does not occur in 30 seconds, turn control knob to the
OFF position and turn gas off at the source, wait 5 minutes until
gas has cleared and repeat lighting procedure.
9.
After lighting, rotate the Burner Control Knob counter clockwise
to LOW setting. Observe fl ame, make sure all burner ports are
lit. Flame height should be no higher than 13 inches tall.
10.
Adjust the fl ame to the desired height with the
control knob.
Using a Long Match or Lighter
1.
Prior to lighting, use a shovel to move lava rocks for
access to the burner.
2.
Wearing heat resistant gloves, position the burning
long match or burning butane lighter near the side of
the burner. DO NOT lean over the fi re table while
lighting!
3.
Turn control knob counterclockwise to LIGHT.
4.
Remove long match/long butane lighter.
5.
After lighting, use a shovel and heat resistant gloves
to carefully move the lava rocks back into their proper
position and replace the glass panel.
6.
After lighting, rotate the Burner Control Knob counter
clockwise to LOW setting. Observe fl ame, make sure
all burner ports are lit. Flame height should be no
higher than 13 inches tall.
7.
Adjust the fl ame to the desired height with the control
knob.
When using this method to light
your fi re table use heat resistant
gloves and follow the step by
step instructions. Failure to do so
could result in severe injury.
If burner fl ame goes out during operation, immediately
turn the control knob OFF and let the gas clear a
minimum of 5 minutes before attempting to re-light the
fi re table.
Please refer to the trouble shooting pages for
additional support, beginning on page 18.
Using the Igniter
!
!
WARNING
WARNING
HI
OFF
LIGHT
LOW
Control Knob
PUSH
IN