Operating instructions
Peristaltic Pump IP Series
12
5.3.2 IP-40 Model
(Number of shims of 1 mm thickness)
:
a) NR, NBR, EPDM, HYPALON, NR-A and NBR-A:
Bar
1/min
0-19
20-39
40-59
60-79
80-99
0.5
4
4
4
4
3
2.0
5
4
4
4
4
4.0*
5
5
5
4
4
6.0
6
5
5
–
–
8.0
6
6
–
–
–
*Factoring default setting if working pressure is not informed.
b) Norprene:
Bar
1/min
0-19
20-39
40-59
60-79
80-99
0.5
14
14
14
14
14
2.0*
14
14
14
14
14
*Factoring default setting if working pressure is not informed.
5.3.3 IP-50 Model
(Number of shims of 1 mm thickness)
:
a) NR, NBR, EPDM, HYPALON, NR-A and NBR-A:
Bar
1/min
0-19
20-39
40-59
60-79
80-99
0.5
1
1
1
0
0
2.0
2
1
1
1
1
4.0*
2
2
2
2
2
6.0
3
3
3
3
–
8.0
4
3
–
–
–
*Factoring default setting if working pressure is not informed.