background image

4

• 

 is the reduce  ame button. Press this to reduce the height/intensity of your  ame. You will hear an audible beep 

when you reach the minimum level

• 

 is the increase  ame button. Press this to increase the height/intensity of your  ame. You will hear an audible 

beep when you reach the maximum level

• 

 is the reduce  re crackling sound. Press this to reduce the volume of the crackling sound. The minimum volume 

for this is off

• 

 is the increase  re crackling sound. Press this to increase the volume of the crackling sound.

CAS1000

Mains Switch ‘A’:- Controls the electricity supply to the appliance.

Note: This switch must be in the ‘ON’ ( 

) position for the appliance to operate

Button panel ‘A’:- Controls the functioning of the left side of appliance

• 

 is the on/standby button. Press it to turn on and off the  ame effect. Turning it on will be indicated by the light 

activating. Be careful not to look directly into the LED’s. These are very bright.  Although the main lights operate 

immediately it will take a further 45 seconds before the  ame effect starts. 

• 

 is the Pairing button. This will pair your remote control to the receiver. See ‘Remote Control Operation’ for details

• 

 is the test mode button. This will be used by the manufacturer and the Service Engineer

• 

 is the reduce  ame button. Press this to reduce the height/intensity of your  ame. You will hear an audible beep 

when you reach the minimum level

• 

 is the increase  ame button. Press this to increase the height/intensity of your  ame. You will hear an audible 

beep when you reach the maximum level

• 

 is the reduce  re crackling sound. Press this to reduce the volume of the crackling sound. The minimum volume 

for this is off

• 

 is the increase  re crackling sound. Press this to increase the volume of the crackling sound.

Button panel ‘B’:- Controls the functioning of the right side of appliance

• 

 is the test mode button. This will be used by the manufacturer and the Service Engineer

• 

 is the reduce  ame button. Press this to reduce the height/intensity of your  ame. You will hear an audible beep 

when you reach the minimum level

• 

 is the increase  ame button. Press this to increase the height/intensity of your  ame. You will hear an audible 

beep when you reach the maximum level

• 

 is the reduce  re crackling sound. Press this to reduce the volume of the crackling sound. The minimum volume 

for this is off

• 

 is the increase  re crackling sound. Press this to increase the volume of the crackling sound.

GETTING THE DESIRED FLAME EFFECT

1.  Switch the appliance on by pressing the main switch to the on position and pressing the on/standby button. The 

ames will start after 45 seconds. The  ames will be at max height for 5 seconds and then reduce to a nominal level

2.  Press the   and 

 buttons to adjust the  ame to your desired level. Please give the  ame generator time to react 

to the changes you make.

3.  Do not tilt or move the appliance while there is water in the tank or sump

4.  Make sure that the appliance is on a level surface

Once you have made your adjustments to both the  ame height and crackling sound the appliance will keep these 

settings even if you power off the appliance by either the on/standby button or by the main switch. The next time you 

switch on the appliance it will start up as normal, wait 45 seconds for the  ames to start, run at maximum height for 5 

seconds and then revert to the adjusted settings.

REFILLING THE WATER TANK(S)

If you have chosen to operate your appliance by the Water Tanks provided, this section describes how to re ll the Water 

Tank on your CAS500 or CAS1000.

When the water in the tank(s) has been used up, the appliance will shut down the mist generation and cause the LED’s 

to continuously blink twice. In the case of a CAS1000 only one side of the product will blink, this is the side that has run 

out of water. To re ll follow the below steps;

1.  Carefully lift off the fuelbed and set aside. 

2.  Press switch ‘A’ to the OFF (O) position. 

3.  Lift off the water tank(s), 1off on CAS500 and 2off on CAS1000 and take them to your water supply e.g. kitchen

4.  Remove the cap by turning it anticlockwise

5. 

Fill with  ltered tap water only

6.  Replace the cap by turning it clockwise. Be careful not to over tighten

7.  Place the bottle(s) back into position and wait until they  nish  lling the sump(s)

8.  Press switch ‘A’ to the ON (I) position

Summary of Contents for OPTIMYST CAS1000

Page 1: ...European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC Approval Number ESV160149 08 532...

Page 2: ...ards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of this product can become very hot and...

Page 3: ...nclosure above the product This will allow enough space above the product to allow the ames to form fully and not to be obstructed This product needs free ventilation from underneath to operate correc...

Page 4: ...Log Fuelbed out of its packaging CAUTION The fuelbed weighs 5kg Be sure to only lift the Fuelbed by the two center logs Fig 5 These are the strongest Place the Fuelbed on top of the appliance there a...

Page 5: ...inimum level is the increase ame button Press this to increase the height intensity of your ame You will hear an audible beep when you reach the maximum level is the reduce re crackling sound Press th...

Page 6: ...the minimum level is the increase ame button for the right had side of the appliance Press this to increase the height intensity of your ame You will hear an audible beep when you reach the maximum l...

Page 7: ...in the clip with one hand and with the other lift the nozzle our of the clip Repeat this for the right side Fig 11 The nozzle is now released lift this off and place aside Fig 12 6 Gently lift up the...

Page 8: ...ould not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice PATENT PATENT APPLICATION Products within the Optimy...

Page 9: ...Check that there are no leaks in the tubes check that the ball valve is in the on position Once the mains water has been re established turn back on the product as mentioned above Product will not op...

Page 10: ...pplicable laws 2 Registration You must register to receive the bene t of this warranty by completing the warranty registration on our website www real ame com au or completing and mailing the attached...

Page 11: ...sumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or r...

Page 12: ...MODEL DIM A CAS500 508mm CAS1000 1017mm Fig 1 Fig 2 Fig 3a Fig 3b Fig 3c Fig 5 Fig 4...

Page 13: ...C A B Fig 6 Fig 7 Fig 8b CAS500 CAS1000 Fig 8a Fig 10 Fig 11...

Page 14: ...CAS1000 CAS500 Fig 9 Switch A Fig 12 Fig 13 Fig 14 L N E A Fig 15 Fig 16...

Page 15: ...210cm2 210cm2 420cm2 420cm2 Fig 17 Fig 18...

Page 16: ...elong hotmail com au Sydney NSW Showroom 546 Pacific Highway Chatswood NSW 2067 Ph 02 8905 0189 Fax 02 8905 0192 E mail info realflame com au Miranda NSW Showroom 36 Kareena Rd Miranda NSW 2228 Ph 02...

Reviews: