ICENI/AI-04  

 

 

 

UNPACKING & INITIAL PREPARATION FOR USE 

 
6.1 

Unpacking 

 

The module should be removed from the sealed bag inside the protective cardboard 
carton. All packaging should be disposed of in an appropriate way. 
 
 

6.2 

Node Assembly 

 

The module is designed to clip and fit onto TS 35 DIN terminal rail (both standard 
and deep types) with other Iceni modules to form a node. A metal clip is provided on 
the base of each module for this purpose. 
 
 
 
 
      DIN rail clip 
 
 
 
 
An Iceni node can be mounted in both vertical and horizontal orientations according 
to terminal rail layout. Assembly of the Iceni node can be achieved in one of two 
ways: 
 

o

  The Iceni node (including the ICENI/AI-04 module) can be assembled on a 

bench and then fitted into place on the DIN rail with a slight tilting action. It is 
important that the metal DIN rail latch on the underside of each module engages 
properly with the rail to retain the modules in place. 

 

o

  The ICENI/AI-04 module can be fitted with other modules one at a time on the 

DIN rail with a slight tilting action. It is important that the metal DIN rail latch on 
the underside of each module engages properly with the rail to retain the module 
in place. The modules can then be pressed together tightly to ensure that each 
module plugs into its neighbour to form the node. 

 

 

6.3 

Node Disassembly 

 

Disassembly of the Iceni node is essentially the reverse of the procedure above and 
can be achieved in one of two ways: 
 

o

  Each module can be separated from the next on the rail. The metal DIN rail latch 

can then be operated with a small screwdriver and the modules removed with a 
tilting action, one by one. 

 

o

  The metal DIN rail latches for all modules can be released in turn with a small 

screwdriver until the Iceni node is free to be removed with a tilting action. The 
modules can then be separated from each other. 

Pub_3645                  

                                                                                     

Page 14 of 25

                          

 

Summary of Contents for ICENI/AI-04

Page 1: ...Instruction Manual ICENI AI 04 4 Channel RTD Input Module Pub_3645 Issue 1...

Page 2: ...lateurs Europa Ltd 2014 The contents of this document are the exclusive Property of Regulateurs Europa Ltd They must not be copied or reproduced without the written authorisation of the Company Pub_36...

Page 3: ...11 5 1 2 Signal Channels 11 5 1 3 Fault Status Indication 11 5 1 4 Signal Isolation 11 5 1 5 Field Wiring Termination 12 5 2 Mechanical Properties 13 5 2 1 Temperature Range 13 5 2 2 Material 13 5 2 3...

Page 4: ...18 9 MODULE OPERATION 19 9 1 Module Configuration 19 9 2 Signal Configuration 19 9 3 Signal Measurements 19 9 4 Module Signal Failure Detection 20 10 DATA COMMUNICATIONS TO MASTER MODULE 22 11 SOFTWAR...

Page 5: ...sity of application certain items may differ in detail It should be noted that these instructions are issued for general information and do not constitute a specification of the equipment Whilst reser...

Page 6: ...on each side of the module and the field wiring connectors at the top of the module Ensure that any wires are fitted securely into terminals 2 3 Signal Connection If the module requires configuration...

Page 7: ...ode master signal conditioning modules power module x8 in this example supply module According to the mix of signal conditioning modules the Iceni node manages the measurement and generation of electr...

Page 8: ...supply between modules All modules have a 10 way ICENIbus connector on both sides of the lower housing although for end modules master and main power supply one side connector will be supplied fitted...

Page 9: ...e numbers marked on the Iceni housing This arrangement identifies the connector to its location on the module When fitted properly the field wiring connectors are held securely in the module housing I...

Page 10: ...features o Four sensor inputs each configurable to support PT100 PT200 PT500 and PT1000 type sensors alpha 0 00385 o Signal fault indication via illuminated channel indicator on ICENI AI 04 module an...

Page 11: ...and or high resistance sensor types Accuracy 0 5 fsd Update rates 10Hz at master module 20Hz internal Signal filtering software and hardware Input resistance 1MOhm Signal measurement range 200 C to 85...

Page 12: ...ICENI AI 04 5 1 5 Field Wiring Termination 4 x 4 way free part sockets with screw terminals Cage clamp option available Wiring cross section strip length 0 14 to 0 5mm2 7mm Pub_3645 Page 12 of 25...

Page 13: ...age 40 C to 85 C 40 F to 185 F 5 2 2 Material Enclosure Polyamide Labels Polyester Membrane overlay Polyester 5 2 3 Weight Module weight including free part screw terminals 130g approx 5 2 4 Ingress P...

Page 14: ...he underside of each module engages properly with the rail to retain the modules in place o The ICENI AI 04 module can be fitted with other modules one at a time on the DIN rail with a slight tilting...

Page 15: ...y of the yellow locations shown in the diagram below according to the total number of signal conditioning modules assembled in the node 1 16 Modules should be assembled with population starting at pos...

Page 16: ...MINAL DESCRIPTION 13 14 LOOP 15 R 4 16 R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 not connected 7 2 Wiring Schematic R LOOP RTD ICENI AI 04 R Notes o For 3 wire operation wiring for R R and LOOP must be...

Page 17: ...nected to a clean earth ground point In many applications this would be the chassis of the product It is recommended that screened signal cables are used with the screen connected to a clean earth gro...

Page 18: ...f the module presents the following status indicators module health status channels 1 to 4 signal status 8 2 Pushbutton The top face of the module presents a pushbutton for access to channel informati...

Page 19: ...has been removed for greater than two minutes each channel will take up to approximately 15 seconds to initialise and present a measurement value However the value may not be accurate until the modul...

Page 20: ...ensor cable loop open circuit major signal fault measured signal fault o circuit off 9999 C 9999 F 4 The faults above are non latching and will self reset when the failure condition is removed In addi...

Page 21: ...ICENI AI 04 value healthy Pub_3645 Page 21 of 25...

Page 22: ...ALUE CHANNEL 3 STATUS VALUE CHANNEL 4 STATUS VALUE CHANNEL UNAVAILABLE CHANNEL UNAVAILABLE CHANNEL UNAVAILABLE CHANNEL UNAVAILABLE MEASURED DRIVEN SIGNAL VALUES CHANNEL 1 MEASURED DRIVEN VALUE if avai...

Page 23: ...ICENI AI 04 11 SOFTWARE VERSION This instruction manual is valid for the following releases of software K0013 001 Pub_3645 Page 23 of 25...

Page 24: ...ld be used The product part number and serial number where available should be referenced Regulateurs Europa Ltd Port Lane Colchester Essex C01 2NX United Kingdom Tel 44 0 1206 799556 Fax 44 0 1206 79...

Page 25: ...ICENI AI 04 Pub_3645 Page 25 of 25 13 REVISION HISTORY REVISION DATE AUTHOR CHANGES 1 22 04 14 MMB Original Regulateurs Europa Ltd Port Lane Colchester Essex United Kingdom CO1 2NX...

Reviews: