2 .13 .6 External air sensor
A
under roof
B
under a terrace
C
provide a small roof if installed freely on a wall
D
external air sensor
E
protection box
F
connection terminal strip
10
D
E
F
A
B
C
NORD
2 .13 .7 Ethernet connection by means of switch
The touch screen interface is connected to the INN-PDC-02 con-
trolled by means of an Ethernet web server which may be con-
nected to a switch and to a modem for controlling and supervis-
ing the device from any Internet connection.
Additionally, the web server board can send an email to three
different recipients if any operating alarm appears. This message
can be used to inform the service centre which can connect (if
you authorise them to do so) to your device to understand the
reason for faults and in many cases solve the problem without
needing to intervene on-site.
Contact the Technical Service to activate this function.
2 .14 Solar unit connection
The device with solar integration is provided complete with
electronic control unit which was pre-wired at the factory.
sensor S1 must be positioned on the solar collector.
S1
Solar panel sensor
S2
Hot water tank sensor
OUT1 PSO solar pump output
POMPA SOLARE