Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
16
9.7
UP-Stop-down operation:
There are two inputs for connecting a up-stop-down operation, X7 and X8. X7 is used for
operation on the lid of the cabinet and X8 can be used for an external operation. If X7 or X8 is not
used, connections 1 and 2 for the Stop function must be connected with a wire bridge (see Fig. 9).
Cover unit control
External control
Figure 9 Connecting up-stop-down operation
9.8
Photocell:
A photocell can be connected to X10. There is also a 24VDC power supply on X10 for the power
supply of a photocell or any other accessories like e.g. A receiver. In addition, an entrance for the
NC contact of the photocell is also provided. If no photocell is applied, this input must be
connected with a wire bridge (see Fig. 10).
Figure 10 Connecting Photocell
9.9
Light curtain:
A PNP and SSR light curtain
can
be connected to X10.
AN OSE light curtain can be connected to
X12.
There is also a 24VDC power supply available on X10 for a
light curtain. In addition, an
entrance for the NC contact of
The light curtain
is also
provided. If no
light curtain is applied,
this input must be connected with a wire bridge
(see Fig. 11).
Figure 11 connecting light curtain