70
MOTOSCOPE INDUSTRIALI
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
Periodic maintenance and checks
Every ... hours
8
40
125
500
1500
1
Check level of water in batteries
•
2
Check carbon brushes of suction fan and drive motors
•
3
Check that the main brush is not entangled with string,
wire, etc.
•
4
Check filter cartridges
•
5
Replace filter cartridges
•
6
Check main brush trace
•
7
Check tension of the belts
•
8
Grease steering chain
•
Periodic maintenance and checks
1) The motor-sweeper must be inspected by a specialist technician who checks its safety or for any damage or defects in the
following cases:
•
before it is put into operation
•
after modifications or repairs
•
at regular intervals, as indicated in the “Routine maintenance and control operations” table.
2) Every six months check that the safety devices are in good working order; the inspection must be made by authorized
specialist staff.
3) To ensure the sweeper performance, the machine must be overhauled by RCM staff every 5 years.
4) The person in charge of the machine must make an annual check on its condition. During this check, he must decide whether
the motor-sweeper still complies with the current safety regulations, and then apply a marker plate to the machine to
indicate that the check has been made.