background image

5

ENGLISH

10.

 There are numerous mechanical and electrical factors to be considered when installing 

a professional audio system (in addition to those which are strictly acoustic, such as sound 
pressure, angles of coverage, frequency response, etc.).

11.

 Hearing loss

Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure 
level that leads to hearing loss is different from person to person and depends on the dura-
tion of exposure. To prevent potentially dangerous exposure to high levels of acoustic pres-
sure, anyone who is exposed to these levels should use adequate protection devices. When 
a transducer capable of producing high sound levels is being used, it is therefore necessary 
to wear ear plugs or protective earphones. See the manual technical specifications to know 
the maximum sound pressure level.

IMPORTANT NOTES

To prevent the occurrence of noise on line signal cables, use screened cables only and avoid 
putting them close to:

 -

Equipment that produces high-intensity electromagnetic fields.

 -

Power cables.

 -

Loudspeaker lines.

OPERATING PRECAUTIONS

 -

Place this product far from any heat sources and always ensure an adequate air circula-
tion around it.

 -

Do not overload this product for a long time.

 -

Never force the control elements (keys, knobs, etc. ).

 -

Do not use solvents, alcohol, benzene or other volatile substances for cleaning the ex-
ternal parts of this product.

IMPORTANT NOTES

Before connecting and using this product, please read this instruction manual carefully and 
keep it on hand for future reference. The manual is to be considered an integral part of 
this product and must accompany it when it changes ownership as a reference for correct 
installation and use as well as for the safety precautions. RCF S.p.A. will not assume any 
responsibility for the incorrect installation and / or use of this product.

WARNING

: To prevent the risk of fire or electric shock, never expose this product to rain 

or humidity.

IMPORTANT NOTES

IMPORTANT NOTES

WARNING

OPERATING 

PRECAUTIONS

Summary of Contents for SUB 8004-AS

Page 1: ...OWNER MANUAL SUB 8006 AS SUB 8004 AS HIGH OUTPUT ACTIVE SUBWOOFERS...

Page 2: ......

Page 3: ...3 ENGLISH ITALIANO LANGUAGE 4 11...

Page 4: ...an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this product is not used for a long period disconnect the...

Page 5: ...ables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Loudspeaker lines OPERATING PRECAUTIONS Place this product far...

Page 6: ...t ergonomics and is the result of extensive combined functional and acoustic research The Sub Series Subwoofer cabinets are built in birch plywood and are designed to dampen down vibrations even at ma...

Page 7: ...s is available from XOVER OUTPUT XLR 7 TIME DELAY ENCODER This encoder provides a time delay setting expressed in meters 8 POWER INDICATOR Power on indicator When the power cord is connected and the p...

Page 8: ...ll the subwoofers in the same group to the exact same delay It is possible to create subwoofer cardioid systems using groups of three modules A group is made of three modules the group shall be made a...

Page 9: ...FUSE 220 240V 2XFUSE T 6 3 A H 250 V 1 X SUB 8004 AS 100 120V 2XFUSE T 10 A H 250 V 1 X SUB 8004 AS It is possible to stack HDL 20 A on top of SUB 8006 AS in vertical or horizontal position It is pos...

Page 10: ...FLY BAR 13360138 AC POWER CABLE 6XTTL55 POWER CABLE 1 piece for EVERY 6 pieces of SUB8006 AS 13360145 AC POWER BOX 6XTTL55 EUROPEAN STAGE BOX TO POWER 6 SUB 8006 AS Full compatibility with Socapex SL...

Page 11: ...e riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecchio non funziona o funziona in...

Page 12: ...a studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0dB usare solo cavi schermati ed evit...

Page 13: ...ari ed il risultato di estese ricerche sia acustiche che funzionali I mobili sono costruiti in multistrato di betulla e sono progettati in modo da smorzare le vibrazioni della struttura anche ai massi...

Page 14: ...over disponibile per il satellite all uscita di segnale audio XOVER OUTPUT XLR 7 ENCODER RITARDOTEMPORALE Permette l impostazione del ritardo temporale in metri 8 POWER INDICATOR Indicazione di alimen...

Page 15: ...controllo di livello a seconda delle necessit Il ritardo espresso in metri Per impostare il ritardo ruotare sino a raggiungere il ritardo desiderato In caso di utilizzo di pi subwoofer assicurarsi che...

Page 16: ...E Non sospendere mai il diffusore per mezzo delle maniglie Le maniglie sono state progettate per il trasporto del diffusore non per la sua sospensione ATTENZIONE Assicurarsi sempre che la richiesta ma...

Page 17: ...8 AC POWER CABLE 6XTTL55 CAVO ALIMENTAZIONE Un cavo alimenta 6 subwoofers SUB 8006 AS 13360145 AC POWER BOX 6XTTL55 EUROPEAN STAGE BOX per alimentare 6 SUB 8006 AS connessi ad una presa 32 ampere trif...

Page 18: ...30 120 Hz 141 dB 90 Hz 120 Hz 2 x 18 woofer 4 0 voice coil 2 x 1250 Watt 709 x 1109 x 700 mm 90 Kg Baltic birch plywood 4 x die cast handles 30 120 Hz 136 dB 90 Hz 120 Hz 18 woofer 4 0 voice coil 1250...

Page 19: ......

Page 20: ...9 0522 274 411 e mail info rcf it RCF UK e mail info rcfaudio co uk RCF France e mail france rcf it RCF Germany e mail germany rcf it RCF Spain e mail info rcfaudio es RCF Belgium e mail belgium rcf i...

Reviews: