SAFETY PRECAUTIONS
1.

 All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2. POWER SUPPLY FROM MAINS

a.  The mains voltage is sufficiently high to involve a risk of electrocution; install and con-

nect this product before plugging it in.

b.  Before powering up, make sure that all the connections have been made correctly and 

the voltage of your mains corresponds to the voltage shown on the rating plate on the 
unit, if not, please contact your RCF dealer.

c.  The metallic parts of the unit are earthed through the power cable. An apparatus with 

CLASS I construction shall be connected to a mains socket outlet with a protective 
earthing connection.

d.  Protect the power cable from damage; make sure it is positioned in a way that it can-

not be stepped on or crushed by objects.

e.  To prevent the risk of electric shock, never open this product: there are no parts inside 

that the user needs to access.

3.

 Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit. This apparatus shall not be exposed to dripping or splashing. No objects filled with 
liquid, such as vases, shall be placed on this apparatus. No naked sources (such as lighted 
candles) should be placed on this apparatus.

4.

 Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.
Contact your authorized service centre or qualified personnel should any of the following 
occur:

 -

The product does not function (or functions in an anomalous way).

 -

The power cable has been damaged.

 -

Objects or liquids have got in the unit.

 -

The product has been subject to a heavy impact.

5.

 If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately 

and disconnect the power cable.

7.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 
this product by using elements that are unsuitable or not specific for this purpose. Also 
check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.), and the components used for attachment (screw anchors, screws, brackets 
not supplied by RCF etc.), which must guarantee the security of the system / installation 
over time, also considering, for example, the mechanical vibrations normally generated by 
transducers.
To prevent the risk of falling equipment, do not stack multiple units of this product unless 
this possibility is specified in the user manual.

8. RCF S.p.A. strongly recommends this product is only installed by profession-
al qualified installers (or specialised firms) who can ensure correct installation 
and certify it according to the regulations in force.
The entire audio system must comply with the current standards and regula-
tions regarding electrical systems.

9.

 Supports and trolleys

The equipment should be only used on trolleys or supports, where necessary, that are rec-
ommended by the manufacturer. The equipment / support / trolley assembly must be moved 
with extreme caution. Sudden stops, excessive pushing force and uneven floors may cause 
the assembly to overturn.

SAFETY

PRECAUTIONS

IMPORTANT

Summary of Contents for SUB 8004-AS

Page 1: ...OWNER MANUAL SUB 8006 AS SUB 8004 AS HIGH OUTPUT ACTIVE SUBWOOFERS...

Page 2: ......

Page 3: ...3 ENGLISH ITALIANO LANGUAGE 4 11...

Page 4: ...an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this product is not used for a long period disconnect the...

Page 5: ...ables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Loudspeaker lines OPERATING PRECAUTIONS Place this product far...

Page 6: ...t ergonomics and is the result of extensive combined functional and acoustic research The Sub Series Subwoofer cabinets are built in birch plywood and are designed to dampen down vibrations even at ma...

Page 7: ...s is available from XOVER OUTPUT XLR 7 TIME DELAY ENCODER This encoder provides a time delay setting expressed in meters 8 POWER INDICATOR Power on indicator When the power cord is connected and the p...

Page 8: ...ll the subwoofers in the same group to the exact same delay It is possible to create subwoofer cardioid systems using groups of three modules A group is made of three modules the group shall be made a...

Page 9: ...FUSE 220 240V 2XFUSE T 6 3 A H 250 V 1 X SUB 8004 AS 100 120V 2XFUSE T 10 A H 250 V 1 X SUB 8004 AS It is possible to stack HDL 20 A on top of SUB 8006 AS in vertical or horizontal position It is pos...

Page 10: ...FLY BAR 13360138 AC POWER CABLE 6XTTL55 POWER CABLE 1 piece for EVERY 6 pieces of SUB8006 AS 13360145 AC POWER BOX 6XTTL55 EUROPEAN STAGE BOX TO POWER 6 SUB 8006 AS Full compatibility with Socapex SL...

Page 11: ...e riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecchio non funziona o funziona in...

Page 12: ...a studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0dB usare solo cavi schermati ed evit...

Page 13: ...ari ed il risultato di estese ricerche sia acustiche che funzionali I mobili sono costruiti in multistrato di betulla e sono progettati in modo da smorzare le vibrazioni della struttura anche ai massi...

Page 14: ...over disponibile per il satellite all uscita di segnale audio XOVER OUTPUT XLR 7 ENCODER RITARDOTEMPORALE Permette l impostazione del ritardo temporale in metri 8 POWER INDICATOR Indicazione di alimen...

Page 15: ...controllo di livello a seconda delle necessit Il ritardo espresso in metri Per impostare il ritardo ruotare sino a raggiungere il ritardo desiderato In caso di utilizzo di pi subwoofer assicurarsi che...

Page 16: ...E Non sospendere mai il diffusore per mezzo delle maniglie Le maniglie sono state progettate per il trasporto del diffusore non per la sua sospensione ATTENZIONE Assicurarsi sempre che la richiesta ma...

Page 17: ...8 AC POWER CABLE 6XTTL55 CAVO ALIMENTAZIONE Un cavo alimenta 6 subwoofers SUB 8006 AS 13360145 AC POWER BOX 6XTTL55 EUROPEAN STAGE BOX per alimentare 6 SUB 8006 AS connessi ad una presa 32 ampere trif...

Page 18: ...30 120 Hz 141 dB 90 Hz 120 Hz 2 x 18 woofer 4 0 voice coil 2 x 1250 Watt 709 x 1109 x 700 mm 90 Kg Baltic birch plywood 4 x die cast handles 30 120 Hz 136 dB 90 Hz 120 Hz 18 woofer 4 0 voice coil 1250...

Page 19: ......

Page 20: ...9 0522 274 411 e mail info rcf it RCF UK e mail info rcfaudio co uk RCF France e mail france rcf it RCF Germany e mail germany rcf it RCF Spain e mail info rcfaudio es RCF Belgium e mail belgium rcf i...

Reviews: