Main Power Connection
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this
equipment.
Warning:
Take care when connecting units to the supply circuit so that wiring is not overloaded.
Warning:
Installation of the equipment must comply with local and national electrical codes.
Taking all appropriate safety precautions, bring supply wiring into the RC5 enclosure through the attached
cable gland at the bottom left of the enclosure. Power wiring must enter near the connection wires on the
internal Class 2 power supply.
Connect the incoming AC line and neutral wires to the line and neutral wires on the Class 2 power supply
using the provided Wago connector. Follow instructions and procedures provided by Wago for part number
222-412.
Keep internal AC wiring short and neat, without excess length within the RC5 EASS IP65 enclosure.
Cable-tie the incoming AC wiring to the Class 2 power supply wiring in a position that ensures the Wago
connector remains below the power supply, within the power wiring area outlined by white lines on the circuit
board.
Important:
Remove only as much insulation as specified in instructions for Wago connectors,
typically 9 - 10mm. No bare wire should be visible when Wago connections are closed and complete.
If present, a ground or drain wire may be connected to the screw at the bottom center of the RC5 circuit
board. This screw is marked POWER GROUND. Grounding is not strictly required, because the enclosure is
non-conductive, the Class 2 power supply is fully isolated, and transceiver electronics are operating at 12VDC
and not more than 1A.