Troubleshooting
Problem
Probable Cause
Solution
Insufficient water delivered to WC pan
Water supply pressure issue
Check inlet water supply pressure and
that a minimum of 300kPa and
a maximum of 500kPa is available.
Incorrect water supply pipe size
Ensure that a minimum 25mm water
supply is connected to the flush valve.
If multiple flush valves are supplied off
the same service, refer to the hydraulic
design and subsequent pipe sizing
to allow for probable simultaneous
demand.
WC pan flush volume issue
Ensure the WELS rating of the WC pan
is comparable to the WELS rating of
the flush valve.
Incorrect timing setting of flush valve
Master-Trol at stated inlet pressure.
'
6.0 Maintenance
Spare Parts
Note:
This product should be installed, by suitably qualified persons, in a fit for purpose application, to suitable materials,
using suitable fixings and comply with any relevant codes. It should be inspected periodically for signs of wear and tear that
may affect performance or safety.
Dimensions are subject to manufacturer’s tolerance of +/-10mm. Rough-in should be completed with each fixture.
Important:
Installation Instructions are subject to change without notice. Please visit
our websites
for latest revision.
RBA Code No.
Description
RBA8012-999-004
T2 Controller [2020]
RBA7125-999-010
3m, 24/0.20 0.75mm² Figure 8
RBA8010-999-003
Piezo [3m tail]
RBA1882-100