3.1 AS1428.1 Installation
RBA1882-100-007
Rough Wall Opening for plate:
• Fit the flush valve in the required position maintaining a
minimum 700mm distance between the outlet of the vacuum
breaker and the centre line of the flush pipe connected to the WC pan inlet.
• Remove face plate from mounting bracket.
• Install mounting bracket into noggins. Ensure fixing height allows direct access to Flush Valve as shown in image
above.
• Install Piezo buttons in face plate.
• Make electrical connections: Connect Half Flush piezo to
Sensor A.
Connect Full Flush piezo to
Sensor B.
Connect
Solenoid valve to
Valve A.
Connect the Power Pack to
Power 24VAC
.