Manual Operation
.
In the event that there is a problem and the drive will not operate. You can still
operate the legs manually.
To do this first remove the plastic protective sleeve from the drive shaft that
protrudes out from the gearbox (shown below). Put the gear selector in the
neutral
position. This will disengage the motor from the legs. Attach the
eLEG manual handle supplied to the shaft( locked with 10mm L bolt) and wind
as per a normal manual set of landing legs.(Refer page 4 for detailed parts
breakdown).
Red LED
One Flash
A button activation is acknowledged by one flash.
Note: this is only once the controller is initiated as
elsewhere described.
One flash also indicates that the pre-set maximum
increase in load has been exceeded and the
motor has been stopped.
It will flash once again if the button is pressed for the
same direction indicating this is an inhibited operation.
Two Flashes
Indicates that the pre-set maximum load has been
reached and the motor has been stopped
It will flash twice again if the button is pressed for the
same direction indicating this is an inhibited operation.
Three Flashes
This indicates a locked mechanical condition such
as gear failure or motor failure
(Check motor and gearbox)
Four Flashes
An over temperature condition has been reached.
Allow time to cool down before operating again.
Continuous
Indicates that the gear lever is in the neutral
position and you cannot operate the eLEG in that
condition. You must change the lever to a gear
setting before you can operate the eLEG.
Note: this will only occur once the controller is initiated.
Yellow LED
Five Flashes
This indicates that the battery is low and requires
to be charged.
Note: this will only flash once the controller is initiated.
Red LED &
Yellow LED
Two Flashes
Both LED’s will flash twice upon controller
initiation.
Refer operation instructions