16 | 29
www.raytools.net
BM114S SERIES 6KW Laser Cutting Head User Manual
3.2.2
Interface Operation
1.
Move J axis to check if the action is normal (“thread pitch” and direction), J+ indicates
scale 0+.
2.
Slowly moving the J axis so that it meets the positive and negative limit, check whether
the direction and limit signal are normal or not.
3.
By click homing icon, J axis moves to negative direction and do 2
nd
homing when touches
negative limit. In this case the position of zero point coincides with zero focal position.
The homing is finished.
Brown
White & Brown
Green
White & Green
+24V
0V
Up limit
Low limit
Figure
4.7—
Operation
Note:
1.
Click+, the
lens holder
moves
upward. When it touches positive limit, click
-, then
lens
holder
moves
downward to the negative limit.
2.
The direction of origin is negative, and take
lower limit as a sampling signal.
3.
Pitch 2mm, 10000 pulses
per
turn
4.
Positioning speed
is
recommended 50-100mm/s.
3.3
FSCUT (BC)
with velocity mode
3.3.1
Wiring
1.
The motor is AC servo motor, which should connect the end of the drive L1, L2 , L1C and
L2C to
AC
220V L
and N. Please refer to figure 4.8
for the wiring connection mode and figure
4.4 for the driver installation size
2. Limit Signal:
As shown in
figure 4.1
interface