Illustration
Pins Manufacturer Details
Connector used
for module
2-pin Phoenix 1961986
MSTB 2,5/ 2-STF-5,08 BK
Screwdriver: SZS 0,6x3,5, slot-
headed.
Tightening torque min. 0.5 Nm.
Tightening torque max 0.6 Nm.
DC Power IN
(24VDC) - Single
Input
Identified on Hatte-
land Display prod-
uct data sheet as:
“Terminal Block
5.08”
5-pin Phoenix 1827732
MC 1,5/ 5-STF-3,81
Screwdriver: SZS 0,4X2,5 mm
VDE, slot-headed.
Tightening torque min. 0.22 Nm.
Tightening torque max 0.25 Nm.
• RS-422 /
RS-485 / SCOM
(Serial Remote
Control) / Buzzer
• RS-422 /
RS-485 NMEA
(PCA100293-1)
• Digital In-
put/Output
(PCA100297-1)
Identified on Hatte-
land Display prod-
uct data sheet as:
“Terminal Block
3.81”
2.1.1.6
Configuring Housing / Terminal Block Connectors
About this task
Below is a brief illustration that might be useful during configuration and installation of
such connectors. You will need suitable pre-configured cable(s) and tools to configure
the connector(s) and cable(s) that are present in your installation environment. Below
is a sample procedure for a 2-pin DC power connector. The procedure is the same for
other connectors of this type as listed in table above. Unit used as illustration below is for
reference only.
Procedure
1. Unscrew (from top) or make sure that the screw terminal (square area) are fully open,
so you can secure the inserted cables correctly to the loose housing connector (it may
already be plugged into the unit as per factory installation).
Summary of Contents for ECDIS NX Compact
Page 1: ...ECDIS NX Compact System Manual Edition 001 10000000559 ...
Page 4: ...ECDIS NX Compact Table of Contents 10000000559 II Edition 001 ...
Page 6: ...ECDIS NX Compact List of Figures 10000000559 IV Edition 001 ...
Page 8: ...ECDIS NX Compact List of Tables 10000000559 VI Edition 001 ...
Page 10: ...ECDIS NX Compact List of Abbreviations 10000000559 VIII Edition 001 XTE Cross Track Error ...
Page 46: ...ECDIS NX Compact 3 Annex 10000000559 36 Edition 001 3 Annex ...
Page 47: ...Standalone Unit Master Unit in Dual Mode ...
Page 48: ...Backup Unit in Dual Mode ...
Page 49: ...ECDIS24 Refit ...