1. Safety instructions
1. Read this leaflet carefully before commencing to install the SPARTAN unit and retain it
for future use. Installation can only be carried out by suitably qualified personnel.
2. Check the certification to ensure that the Zone, mains supply, ambient temperature
present and ‘T’ rating are suitable for the environment the unit is being installed in.
3. DO NOT open when energised.
4. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec.
5. The SPARTAN unit housing is constructed from marine grade aluminium and toughened
glass, gaskets are silicone sponge, black encapsulant and o rings are silicone rubber,
internally some components are non-metallic. The end user must ensure that these
materials are suitable for the environment the SPARTAN unit will be installed in; Zone 1
and Zone 2 Hazardous areas.
6. Check certification nameplate on side of floodlight/highbay to ascertain type of threaded
cable entry on the luminaire. Select suitably certified ATEX/IEC Ex /UKEX cable glands
and stopper plugs, these must be parallel thread, have a minimum of 5 full thread
engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable
entry devices selected must maintain the IP rating of the luminaire
7. The incoming mains cable should not exceed a temperature rise of 20°C above the
ambient conditions; select suitable cable.
8. To ensure the safety of the equipment, ensure that the ‘flamepath’ on Zone 1 variants
are free from any corrosion. No repairs are possible to flameproof joints – if in doubt
please consult the manufacturer.
9. External fasteners must have a yield strength of at least 600N/mm2
10. On Zone 1 variants the LED assembly contains no user serviceable parts, the luminaire
must not be operated without all the individual LED polycarbonate covers in position, the
IP66 rating must be maintained.
11. When the unit is installed correctly and in accordance with these installation instructions
it will not harm humans or animals.
!
Install in a well
ventilated area
Do not continually
stare at lamp
Isolate mains before
removing cover
1.5m
2. Installation
Mounting SPARTAN Unit
1. To meet the requirements of certification a
MINIMUM
of 2 fixing points must be used,
the fixing points must be suitable for the conditions of use.
2. The line diagrams below are for guidance only – units may be mounted in any orientation
Mounting HP SPARTAN Unit – Floodlight Application