background image

2

3

www.raytecled.com

www.raytecled.com

UK / Europe Tel: +44 (0) 1670 520055

Americas Tel:  +1 613 270 9990

UK / Europe Tel: +44 (0) 1670 520055
Americas Tel:  +1 613 270 9990

1. Safety instructions

1.  Read this leaflet carefully before commencing to install the SPARTAN unit and retain it 

for future use. Installation can only be carried out by suitably qualified personnel.

2.  Check  the  certification  to  ensure  that  the  Zone,  mains  supply,  ambient  temperature 

present and ‘T’ rating are suitable for the environment the unit is being installed in.

3.  DO NOT open when energised.
4.  If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec.
5.  The SPARTAN unit housing is constructed from marine grade aluminium and toughened 

glass, gaskets are silicone sponge, black encapsulant and o rings are silicone rubber, 

internally  some  components  are  non-metallic.  The  end  user  must  ensure  that  these 

materials are suitable for the environment the SPARTAN unit will be installed in; Zone 1 

and Zone 2 Hazardous areas.

6.  Check certification nameplate on side of floodlight/highbay to ascertain type of threaded 

cable entry on the luminaire. Select suitably certified ATEX/IEC Ex /UKEX cable glands 

and  stopper  plugs,  these  must  be  parallel  thread,  have  a  minimum  of  5  full  thread 

engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-3. The cable 

entry devices selected must maintain the IP rating of the luminaire

7.  The incoming mains cable should not exceed a temperature rise of 20°C above the 

ambient conditions; select suitable cable. 

8.  To ensure the safety of the equipment, ensure that the ‘flamepath’ on Zone 1 variants 

are free from any corrosion. No repairs are possible to flameproof joints – if in doubt 
please consult the manufacturer.

9.  External fasteners must have a yield strength of at least 600N/mm2 
10.  On Zone 1 variants the LED assembly contains no user serviceable parts, the luminaire 

must not be operated without all the individual LED polycarbonate covers in position, the 
IP66 rating must be maintained.

11.  When the unit is installed correctly and in accordance with these installation instructions 

it will not harm humans or animals.

    

!

Install in a well 

ventilated area

Do not continually 

stare at lamp

Isolate mains before  

removing cover

1.5m

2. Installation

Mounting SPARTAN Unit

1.  To meet the requirements of certification a 

MINIMUM

 of 2 fixing points must be used, 

the fixing points must be suitable for the conditions of use. 

2.   The line diagrams below are for guidance only – units may be mounted in any orientation

Mounting HP SPARTAN Unit – Floodlight Application

 151 

 215 

 350 

 536 

 639 

 173 

 200 

 

12 

 30 

 

12 

 151 

 215 

 350 

 536 

 639 

 173 

 200 

 

12 

 30 

 

12 

 151 

 215 

 350 

 536 

 639 

 173 

 200 

 

12 

 30 

 

12 

Reviews: