4. Technical Specification

120W version

300W version

Input Voltage

150-264V AC/DC or 110-254V AC/DC

Input Current (230Vac, full load)

0.52A

1.4A

Consumption

120W

300W

Power Factor (230Vac, full load)

>0.97

Mains Frequency

50/60Hz

Inrush Current  (I

peak

 @50%)

53A, ∆t < 300µs

60A, ∆t < 300µs

Total Harmonic Distortion (230Vac, full load)

≤3%

IP Rating

IP66

Weight (std)

22Kg

23Kg

Dimensions

See previous pages for line diagrams

ATEX  and IECEx and UKEX Rating

See page 6

Twidth

Inrush Current Typical Curve

Ipeak

3. Maintenance

1.  It  is  essential  that  all  SPARTAN  units  are  maintained  in  accordance  with  the 

requirements  of  the  EN60079-17  standard:  (Electrical  apparatus  for  explosive  gas 

atmospheres – other than mines).

2. 

IMPORTANT

.    No  modifications  are  permitted  to  the  unit,  all  spare  parts  must  be 

purchased  from  the  manufacturer,  unauthorized  modifications  or  spare  parts  will 

invalidate certification and make the equipment dangerous.

3.  Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out 

any maintenance work.

4.  The unit has 2 independent power supplies; in the event that a power supply needs to 

be replaced remove the flameproof cover to get access to the power supply. Remove 

the power supply from the mains terminals then remove LED red and black wires. If 

replacing a power supply on a Zone 2 luminaire the orange silicone gasket should 

be replaced at the same time to maintain the restricted breathing properties of the 

enclosure,  the  gasket  is  located  in  the  machined  groove,  all  replacement  gaskets 

must be supplied via Raytec 

5.  Disposal  of  packaging,  SPARTAN  units  and  old  LED  assemblies/power  supplies 

should be carried out in accordance with national regulations.

PROTECTION/CERTIFICATION

PROTECTION/CERTIFICATION – ZONE 1/21 VARIANTS
CML17ATEX1148 or IEC Ex CML17.0074 or CML21UKEX1102

II 2 GD Ex db eb mb IIB T4 Gb 

Ta -50

o

C to +50

o

C

Ex tb IIIC T104°C Db

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC

PROTECTION/CERTIFICATION – ZONE 2/22 VARIANTS
CML17ATEX4149 or IEC Ex CML17.0074 or CML21UKEX4101

II 3 GD Ex nR ec IIC Gc   

Ta -50

o

C to +50

o

C

Ex tb IIIC T104°C Dc

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC

PROTECTION/CERTIFICATION – ZONE 21 DUST ONLY VARIANTS
CML18ATEX3161 or IEC Ex CML18.0087 or CML21UKEX3107

Ex tb  IIIC T104°C Db

Ta -50°C to +50°C

IP66 150-264V AC/DC or 110-254V AC/DC