6
www.raytecled.com
UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
2. The SPARTAN Bulkhead is supplied as standard with the mounting brackets as shown
on the above diagram, other mounting methods/brackets available – please contact
Raytec.
Spartan Bulkhead Standard/Emergency Variant
3. Installer should earth the unit separately – an internal and external earth point are
provided as standard
4. Connect wires to mains supply.
5. If the unit is opened for any reason, disconnect mains –
On emergency luminaires
there may be more than one mains supply
6. All SPARTAN bulkheads have terminal blocks suitable for looping 4mm2 cable,
only one cable should be connected to each terminal block connection
Wire the Mains cable into the terminal block. Provision has been made for this and identified
as the E (Earth), L1 (Live switched), L2 (Live permanent) and N (Neutral) terminals. There
are two pairs of contacts for each of these to facilitate a mains cable that can be looped in
and out of the unit. The L2 terminals on a standard unit are not electrically connected but
allows them to be used on the same circuits as
emergency bulkheads.
N
E
L1
L2
EARTH TO SCREW
PSU
WHITE/RED
WHITE
BLUE
BROWN
GREEN
TO LED's
Typical wiring diagram - Standard Variants
Typical wiring diagram - Emergency Variants
N
E
L1
L2
EARTH TO SCREW
PSU
WHITE/RED
WHITE
BLUE
BROWN
GREEN
TO LED's
BA
TT
ER
Y
RED
RED
BLACK
BLACK
FU
SE
GREY
REMOVE LINK IF 4-CORE CABLE USED