background image

7

®

SS

SS

POWER

CALL FOR

HEAT

STAGE 1

STAGE 2

STAGE 3

SAFETY

IGNITION

FLOW

BLOWER 1

BLOWER 2

ON

STANDBY

PROUDLY MADE IN AMERICA

PROUDLY MADE IN AMERICA

POWER

CALL FOR

HEAT

STAGE 1

STAGE 2

SAFETY

IGNITION

FLOW

BLOWER 1

ON

STANDBY

P/N 901891

POWER

ON

CALL FOR

HEAT

BURNER

FIRING

SERVICE

REQUIRED

OFF

P/N 901927 REV 1

G

 

GAS CONNECTION

H

 

WATER IN

H

 

WATER OUT

T

 

COMBUSTION AIR

INLET DIA.

K

 

OPTIONAL

REAR FLUE

CONNECTION DIA.

T & P GAUGE

VIEW PORT

18-5/8

12-1/8

7-1/2

7-1/8

11-5/8

25

31-1/4

34-1/8

7

6

6-1/2

PRV

1° SLOPE ON JACKET TOP

25-1/2

OPTIONAL GAS CONNECTION

    INLET DIA.

K

 

FLUE 

CONNECTION DIA.

T

 

OPTIONAL COMBUSTION AIR

    INLET DIA.

OPTIONAL 
PUMP COVER

OPTIONAL GAS CONNECTION

    INLET DIA.

T

 

OPTIONAL COMBUSTION AIR

    INLET DIA.

OPTIONAL 
PUMP COVER

MANUAL SHUT-OFF
& DIAGNOSTIC LIGHTS

MANUAL SHUT-OFF
& DIAGNOSTIC LIGHTS

OPTIONAL PUMP

OPTIONAL PUMP

28-1/2

28-1/2

3-1/4

2-1/2

2-1/2

2-1/2

1-3/4

17-3/4

17-3/4

A

B

K

 

FLUE 

CONNECTION DIA.

A

B

W

3-1/4

32-7/8

32-7/8

W

G

 

GAS CONNECTION

H

 

WATER IN

H

 

WATER OUT

T

 

COMBUSTION AIR

INLET DIA.

K

 

OPTIONAL

REAR FLUE

CONNECTION DIA.

T & P GAUGE

VIEW PORT

PRV

1° SLOPE ON JACKET TOP

12-7/8

20-3/8

30-3/8

6-3/4

8-1/4

8-5/8

9-1/2

41-1/4

35-3/4

32-5/8

10-7/8

13-1/4

DRAWING 1 - MODELS HD101-HD401

DRAWING 2 - MODELS 302B-902B

DRAWING 3 - MODELS 992B-2342B

OUTDOOR 
VENT TERMINAL

OUTDOOR 
VENT TERMINAL

MANUAL SHUT-OFF
& DIAGNOSTIC LIGHTS

ON-BOARD

DIAGNOSTIC

CENTER

ON-BOARD

DIAGNOSTIC

CENTER

H

 

WATER IN

G

 

GAS CONNECTION

LOW VOLTAGE CONNECTIONS

H

 

WATER OUT

8-7/8

OPTIONAL PUMP

A

B

K

 

FLUE CONNECTION DIA.

T

 

COMBUSTION AIR DIA.

LINE VOLTAGE CONNECTIONS

26-3/8

19-7/16

16-9/16

1-1/4

5-1/16

18-1/4

8-1/2

19-3/8

22-1/8

23-1/2

26

4-9/16

SEE

PUMP

CHART

1° SLOPE ON JACKET TOP

4-15/16

13-1/2

Summary of Contents for HI DELTA HD101 THRU 2342B

Page 1: ...Models HD101 thru 2342B Models HD101 thru 2342B...

Page 2: ...print Raypak s focus on customer satisfaction goes beyond product design Like all Raypak boilers every Hi Delta is factory fire tested assuring reliable start up upon installation For over 60 years Ra...

Page 3: ...opper finned tubes and optional cupro nickel tubes stand up to even the harshest water conditions 10 Burners Special stainless steel alloy pre mix burners pro vide clean robust combustion and meet all...

Page 4: ...are feet plus clearances All components except pumps and PRV s are contained inside the cabinet so there won t be any gas valves or fans hanging off the unit The units remain fully serviceable even wh...

Page 5: ...amount of water from the main system loop into the boiler to maintain the optimum inlet temperature This approach allows the full capacity of the boiler to be utilized to meet the system load while a...

Page 6: ...3091 1545 1030 773 618 515 442 386 343 309 281 258 238 221 206 402B 399 4111 2055 1370 1028 822 685 587 514 457 411 374 343 316 294 274 502B 500 5152 2576 1717 1288 1030 859 736 644 572 515 468 429 39...

Page 7: ...502B 500 420 435 425 50 25 1 1 4 2 6 6 22 545 6 652B 650 546 566 553 60 1 2 30 1 4 1 1 4 2 8 6 27 1 4 590 6 752B 750 630 653 638 67 1 2 33 3 4 1 1 4 2 8 6 30 3 4 675 6 902B 900 756 783 765 78 39 1 1...

Page 8: ...NUAL SHUT OFF DIAGNOSTIC LIGHTS MANUAL SHUT OFF DIAGNOSTIC LIGHTS OPTIONAL PUMP OPTIONAL PUMP 28 1 2 28 1 2 3 1 4 2 1 2 2 1 2 2 1 2 1 3 4 17 3 4 17 3 4 A B K FLUE CONNECTION DIA A B W 3 1 4 32 7 8 32...

Page 9: ...2 992B 28 60 2 7 5 2 20 83 5 2 9 7 13 132 13 1 23 6 2 1 2 1262B 30 72 4 4 7 9 20 106 9 6 16 6 16 132 14 8 25 3 2 1 2 1532B 30 86 7 1 11 9 20 132 16 5 27 0 20 132 16 5 27 0 2 1 2 1802B 30 101 10 7 17...

Page 10: ...ch Low Gas Pressure Switch Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed N A N A N A N A Manual Reset Adjustable Automatic Reset Adjustable 1 Low Water Cut Off 24V With m...

Reviews: