Raypak HI DELTA HD101 THRU 2342B Brochure & Specs Download Page 2

Raypak’s Hi Delta

Decades of expertise and technological innovations went into
creating the Hi Delta boiler, a product that incorporates features
sought after by engineers, installers and end-users alike.

In 1948, Raypak introduced the first straight copper finned tube
boiler designed with reliability and serviceability in mind. The
tradition continues with Raypak’s Hi Delta model. It’s patented burn-
er “security blanket,” an ingenious enhancement that provides a
perfected air-gas pathway for complete combustion, makes the 
Hi Delta the most adaptable sealed-combustion boiler on the market
today.

While many manufacturers claim simple, convenient heat exchanger
removal, servicing the Hi Delta couldn’t be more straightforward.
Just open the unit from the front and slide it out on built-in runners.

Adding to the Hi Delta’s ease of use is the On-board Diagnostic
Center. In the event of an operating problem, this key enhancement
allows an on-site technician to quickly review the unit’s entire fault
history, in easy to understand “real English”. No cryptic codes to
deal with. Our diagnostic center even offers possible solutions to the
problem at hand.

The Hi Delta product family covers the full spectrum of both indoor
and outdoor applications including space heating, process heating,
pool heating and domestic hot water heating. When installed
indoors, the Hi Delta’s versatility is revealed in smaller vent
diameters, direct-venting and the convenience of stacking without
an increased footprint.

Raypak’s focus on customer satisfaction goes beyond product
design. Like all Raypak boilers, every Hi Delta is factory-fire tested,
assuring reliable start-up upon installation.

For over 60 years, Raypak professionals have earned their reputation
as The Hot Water Management Experts. From system design through
installation and start-up, you can count on your local Raypak
Representative and the backing of the industry’s best sales staff,
applications engineers and service department.

Key Features

19 models from 100,000 to 2,340,000 BTUH

All models indoor/outdoor certified

Efficiency:

84%

Boilers- standard

85%

AFUE HD101-HD301

87%

Available on Models 302BE-2342BE

85%

Water Heaters- standard

98%

Condensing system available

(see Specialty Models)

Patented burner “security blanket” enhances staged
combustion, minimizes installation and start-up issues,
and protects burners from metal fatigue

105ºF minimum inlet water capability on standard models;
120°F on 87% boilers

Copper finned tube heat exchanger; Cupro-nickel available

AB 1953 low lead compliant

Bronze headers standard on water heaters, optional
on boilers

Sidewall venting ready; No extractor needed for
most applications

Ducted combustion air ready; TruSeal

TM

CSA-certified

direct-vent available

Status display and on-baord diagnostic center, real english, no 
codes.

Meets all NOx regulations                                                             

Options

G-20 – Low Gas Pressure (Models 302B-2342B) - CSA-certified
for 4” WC supply pressure, natural gas only.

D-14 – Rear vent option available at time of order 

D-21– TrueSeal direct vent air intake system

A-6 – Right hand water connection 

2

Up to 

87%

thermal efficiency!

Visit our website at 

www.raypak.com

to find the Raypak representative in your area.

Summary of Contents for HI DELTA HD101 THRU 2342B

Page 1: ...Models HD101 thru 2342B Models HD101 thru 2342B...

Page 2: ...print Raypak s focus on customer satisfaction goes beyond product design Like all Raypak boilers every Hi Delta is factory fire tested assuring reliable start up upon installation For over 60 years Ra...

Page 3: ...opper finned tubes and optional cupro nickel tubes stand up to even the harshest water conditions 10 Burners Special stainless steel alloy pre mix burners pro vide clean robust combustion and meet all...

Page 4: ...are feet plus clearances All components except pumps and PRV s are contained inside the cabinet so there won t be any gas valves or fans hanging off the unit The units remain fully serviceable even wh...

Page 5: ...amount of water from the main system loop into the boiler to maintain the optimum inlet temperature This approach allows the full capacity of the boiler to be utilized to meet the system load while a...

Page 6: ...3091 1545 1030 773 618 515 442 386 343 309 281 258 238 221 206 402B 399 4111 2055 1370 1028 822 685 587 514 457 411 374 343 316 294 274 502B 500 5152 2576 1717 1288 1030 859 736 644 572 515 468 429 39...

Page 7: ...502B 500 420 435 425 50 25 1 1 4 2 6 6 22 545 6 652B 650 546 566 553 60 1 2 30 1 4 1 1 4 2 8 6 27 1 4 590 6 752B 750 630 653 638 67 1 2 33 3 4 1 1 4 2 8 6 30 3 4 675 6 902B 900 756 783 765 78 39 1 1...

Page 8: ...NUAL SHUT OFF DIAGNOSTIC LIGHTS MANUAL SHUT OFF DIAGNOSTIC LIGHTS OPTIONAL PUMP OPTIONAL PUMP 28 1 2 28 1 2 3 1 4 2 1 2 2 1 2 2 1 2 1 3 4 17 3 4 17 3 4 A B K FLUE CONNECTION DIA A B W 3 1 4 32 7 8 32...

Page 9: ...2 992B 28 60 2 7 5 2 20 83 5 2 9 7 13 132 13 1 23 6 2 1 2 1262B 30 72 4 4 7 9 20 106 9 6 16 6 16 132 14 8 25 3 2 1 2 1532B 30 86 7 1 11 9 20 132 16 5 27 0 20 132 16 5 27 0 2 1 2 1802B 30 101 10 7 17...

Page 10: ...ch Low Gas Pressure Switch Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed N A N A N A N A Manual Reset Adjustable Automatic Reset Adjustable 1 Low Water Cut Off 24V With m...

Reviews: