Raypak HI DELTA HD101 THRU 2342B Brochure & Specs Download Page 4

4

98%High-efficiency Hi Delta with optional CHX
condensing heating system

Hi Delta with CHX achieves unequaled 98% thermal efficiency at full fire. It combines
the reliability of the Hi Delta boiler with an optional CHX heat exchanger which pre-
vents condensation in the heater’s primary combustion chamber. Self contained sec-
ondary heat exchanger can be inspected and maintained without disturbing the vent
or plumbing connections. The result is an ultra high efficiency heater that lasts.
(See Cat. 1000.17)

Flex Gas

TM

Dual-fuel boilers and water heaters

With its patented, CSA-certified rapid fuel switchover system, the Hi Delta FlexGas
is an ideal solution for interruptible-fuel applications (natural/propane gas).
(See Cat. #1000.20)

Options

SureRack

TM

Kit

The perfect solution for today’s most space challenged equipment rooms.
Stacking two Hi Delta 2342 boilers provides over 4.6MMBTU in just over
26 square feet plus clearances. All components (except pumps and PRV’s)
are contained inside the cabinet, so there won’t be any gas valves or fans
hanging off the unit. The units remain fully serviceable even while racked.

• 

For models 302 thru 2342

• 

No Vent Offset Required

• 

Small Footprint

• 

Fits in Low-Ceiling Room

Heavy-Duty Construction

• 

Easy Assembly

• 

All Hardware Included

Still Allows for Complete Servicing

Sidewall Vent

Category III

Vertical Venting

Category I (Type B)

See Cat. 1000.16 for 

complete SureRack Details

• 

For models 402 thru 2002

• 

Top or rear CHX mounting options

• 

Up to 4.0MMBTU if used with the
SureRack racking system

• 

Fully-engineered rack systems simplify
jobsite installation and set-up

• 

Indoor/Outdoor installation

• 

Fully certified vent systems available

Straight tube heat exchanger outlasts
other designs and facilitates scale-
free operation – ideal for DHW 
applications

• 

For models 302 thru 2342

• 

Changeover takes less than one minute

• 

No mechanical components to remove
or replace

• 

Changerover can be accomplished
while firing: simply turn the key!

• 

Factory-installed and tested system

• 

CSA-Certified

Summary of Contents for HI DELTA HD101 THRU 2342B

Page 1: ...Models HD101 thru 2342B Models HD101 thru 2342B...

Page 2: ...print Raypak s focus on customer satisfaction goes beyond product design Like all Raypak boilers every Hi Delta is factory fire tested assuring reliable start up upon installation For over 60 years Ra...

Page 3: ...opper finned tubes and optional cupro nickel tubes stand up to even the harshest water conditions 10 Burners Special stainless steel alloy pre mix burners pro vide clean robust combustion and meet all...

Page 4: ...are feet plus clearances All components except pumps and PRV s are contained inside the cabinet so there won t be any gas valves or fans hanging off the unit The units remain fully serviceable even wh...

Page 5: ...amount of water from the main system loop into the boiler to maintain the optimum inlet temperature This approach allows the full capacity of the boiler to be utilized to meet the system load while a...

Page 6: ...3091 1545 1030 773 618 515 442 386 343 309 281 258 238 221 206 402B 399 4111 2055 1370 1028 822 685 587 514 457 411 374 343 316 294 274 502B 500 5152 2576 1717 1288 1030 859 736 644 572 515 468 429 39...

Page 7: ...502B 500 420 435 425 50 25 1 1 4 2 6 6 22 545 6 652B 650 546 566 553 60 1 2 30 1 4 1 1 4 2 8 6 27 1 4 590 6 752B 750 630 653 638 67 1 2 33 3 4 1 1 4 2 8 6 30 3 4 675 6 902B 900 756 783 765 78 39 1 1...

Page 8: ...NUAL SHUT OFF DIAGNOSTIC LIGHTS MANUAL SHUT OFF DIAGNOSTIC LIGHTS OPTIONAL PUMP OPTIONAL PUMP 28 1 2 28 1 2 3 1 4 2 1 2 2 1 2 2 1 2 1 3 4 17 3 4 17 3 4 A B K FLUE CONNECTION DIA A B W 3 1 4 32 7 8 32...

Page 9: ...2 992B 28 60 2 7 5 2 20 83 5 2 9 7 13 132 13 1 23 6 2 1 2 1262B 30 72 4 4 7 9 20 106 9 6 16 6 16 132 14 8 25 3 2 1 2 1532B 30 86 7 1 11 9 20 132 16 5 27 0 20 132 16 5 27 0 2 1 2 1802B 30 101 10 7 17...

Page 10: ...ch Low Gas Pressure Switch Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed N A N A N A N A Manual Reset Adjustable Automatic Reset Adjustable 1 Low Water Cut Off 24V With m...

Reviews: