3

FOR INTERMITTENT IGNITION (IID) WITH
HONEYWELL OR ROBERTSHAW GAS VALVE
(For All Models)

1.

STOP

!  Read the safety information above.

2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the appliance.
4. This boiler is equipped with an ignition device
which automatically lights the pilot.  Do not try to light
the pilot by hand.

GAS CONTROL
KNOB SHOWN
IN "ON" POSITION

GAS  INLET

HONEYWELL

(Models 30 - 90)

5.  

For Honeywell Valve: 

Turn gas control knob

clockwise

to "Off".

For Robertshaw Valve: 

Push in and move gas

control lever to "Off" position.

6. Wait 5 minutes to clear out any gas.  Then smell for

gas, including near the floor.  If you smell gas,
STOP! Follow "B" in the safety information above
on this label.  If you don't smell gas, go to the next
step.

7.

For Honeywell Valve: 

Turn gas control counter-

clockwise

to "On".

For Robertshaw Valve:

 Move gas control lever to

"On" position.

GAS CONTROL

KNOB SHOWN
IN "OFF"
POSITION

GAS INLET

Fig. #8934.0

  

ROBERTSHAW

  (All Models)

8. Turn on all electric power to the boiler.
9. Set thermostat to desired setting.
10. If the boiler will not operate, follow the instruction

 "To Turn Off Gas To Boiler" and call your service
technician or gas supplier.

TO TURN OFF GAS TO BOILER

1. Set the thermostat at the lowest setting.
2. Turn off all the electric power to the boiler if service

Fig. #8087.0

is to be performed.

3.

For Honeywell Valve:

Turn gas control knob clockwise

       to "Off".

Make sure knob rest against stop.

For Robertshaw Valve:

Push in and move gas control lever to "Off"
position.

HONEYWELL PILOT

CAUTION: 

Should overheating occur or the gas sup-

ply fails to shut off, 

DO NOT 

turn off or disconnect the

electrical supply to the pump.  Instead, shut off the gas
supply at a location external to the appliance.  Failure
to observe this precaution may aggravate the over-
heated condition resulting in possible damage to the
boiler and injury to the user.

INSPECTION  AND  MAINTENANCE
PROCEDURES

       It is a good practice to make a periodic inspection
of the boiler.  It is recommended that the home owner
or user check's the boiler after the first and third month
of operation, and then on an annual basis, or more
often if desired.  It is also recommended to have a
qualified service agency check the boiler before each
heating season, or at anytime there may be an indica-
tion of a problem.

DANGER:

  Keep boiler area clear and free from

combustibles and flammable materials.  Do not o b -
struct the flow of combustion and ventilating air into
the boiler enclosure.  Failure to observe these safety
precautions  can cause fire, explosion, or asphyxia-
tion.

BLUE  FLAME

Fig. #9295

Summary of Contents for H-0030B

Page 1: ...n operation but contact a qualified service agency FLAME ROLL OUT SAFETY SHUT OFF SYSTEM This boiler is equipped with a flame roll out safety shut off system designed to shut off the main burner gas in the event of sustained flame roll out In the event the flame roll out safety system is actu ated do not attempt to place the boiler in operation but contact a qualified service agency CAUTION Improp...

Page 2: ... and call your service technician or gas supplier 9 Stand to the side of the heater and move the gas control lever counterclockwise to ON 10 Turn on all electric power to the appliance 11 Set the thermostat to the desired setting TO TURN OFF GAS TO THE BOILER 1 Set the thermostat to the lowest setting 2 Turn off all electric power to the appliance 3 Push in and move gas control lever counter clock...

Page 3: ...F GAS TO BOILER 1 Set the thermostat at the lowest setting 2 Turn off all the electric power to the boiler if service Fig 8087 0 is to be performed 3 For Honeywell Valve Turn gas control knob clockwise to Off Make sure knob rest against stop For Robertshaw Valve Push in and move gas control lever to Off position HONEYWELL PILOT CAUTION Should overheating occur or the gas sup ply fails to shut off ...

Page 4: ...for evidence of water leakage This should be corrected to prevent any possible damage to electrical components of the boiler CAUTION In case of a prolonged power failure during freezing weather conditions boiler and piping system must be drained completely to avoid possible damage to the heating system To prevent the potential freezing damage to the heating system it is recommended that the follow...

Reviews: