Reprogramming Light or Additional Light

Your garage door opener remote light has already been programmed at the factory to 
operate with your opener. Any additional or replacement remote lights will need to be 
programmed.

1.  Press the LEARN button on the light until the LED comes ON.

2.   Activate the garage door opener using the hand-held remote, door control, or keyless 

entry. 

3.  The code has been programmed when the remote light comes on.

Additional Programming for the Keyless Entry (Not 
Provided)

TO CHANGE AN EXISTING, KNOWN PIN

If the existing PIN is known, it may be changed by one person without using a ladder.

1.   Press the four buttons for the present PIN, then press and hold the # button. Release 

the # button.

2.   Press the new 4-digit PIN you have chosen, then press ENTER.

Test by pressing the new PIN, then press ENTER. The door should move.

TO SET A TEMPORARY PIN

You may authorize access by visitors or service people with a temporary 4-digit PIN. After 
a programmed number of hours or number of accesses, this temporary PIN expires and 
will no longer open the door. It can be used to close the door even after it has expired. To 
set a temporary PIN:

1.   Press the four buttons for your personal entry PIN (not the last temporary PIN), then 

press and hold the 

✽ 

button. Release the button.

2.   Press the temporary 4-digit PIN you have chosen, then press ENTER. 

3.   To set the number of hours this temporary PIN will work, press the number of hours 

(up to 255), then press 

.

OR

3.   To set the number of times this temporary PIN will open door, press the number of 

times (up to 255), then press #.

Test by pressing the four buttons for the temporary PIN, then press ENTER. The door 
should move. If the temporary PIN was set to a certain number of openings, remember 
that the test has used up one opening. To clear the temporary password, repeat steps 1-3, 
setting the number of hours or times to 0 in step 3.

ONE BUTTON CLOSE: 

The garage door opener can be closed by pressing only the ENTER button if the one 
button close feature has been activated. This feature has been activated at the factory. 
To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds. The 
keypad will blink twice when the one button close is active. The keypad will blink four 
times when one button close is deactivated.

Summary of Contents for Premium series 8500RGD Prodigy II

Page 1: ...of door operation per hour This garage door opener is ONLY compatible with MyQ and Security 2 0 accessories This product is intended for installation only by trained garage door technicians This product may require adjustments to door springs and or track configurations This product is not intended for use on low headroom tracks or garage doors utilizing extension springs For Residential and Light...

Page 2: ... Door Opener 7 INSTALLATION 7 Position and Mount the Garage Door Opener 8 Attach the Emergency Release Rope and Handle 9 Install Power Door Lock 9 Attach the Cable Tension Monitor Required 10 Install the Door Control MyQ Control Panel 11 Install Remote Light 12 Install the Protector System 13 Connect Power 16 Install the Battery Backup optional 18 ADJUSTMENT 19 Program the Travel Limits 19 Set the...

Page 3: ...extend at least 1 5 inches 2 5 12 7 cm past the bearing plate This may vary depending on your installation requirements e An electric outlet is required within 6 feet 1 83 m of the installation area If outlet does not exist contact a qualified electrician f Depending upon garage construction extension brackets or wood blocks may be needed to install safety reversing sensors g Alternate floor mountin...

Page 4: ...es of door operation per hour To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may NOT reverse when required NEVER try to loosen move or adjust garage door door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension Disable ALL locks and remove ALL r...

Page 5: ... The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Labels and Literature Hardware Accessories included with the garage door opener will vary depending on the model purchased If anything is missing carefully check the packing material Hex Screw 14 10x1 7 8 4 Screw 6x1 1 4 2 Machine Screw 6x1 2 Carriage Bolt...

Page 6: ...e that the collar is seated all the way on motor shaft until stop is reached 3 Position the collar so the screws are facing out and are accessible when attached to the torsion bar 4 Tighten the screws on both sides of the collar equally to secure collar to the motor shaft to 12 14 ft lbs of torque NOTE Do not tighten set screws until indicated Attach the Collar to the Garage Door Opener Assembly 1...

Page 7: ...rage door opener to power source until instructed to do so 7 NEVER wear watches rings or loose clothing while installing or servicing the garage door opener They could be caught in door or operator mechanisms 8 Install wall mounted door control within sight of the door out of reach of children at minimum height of 5 feet 1 5 m away from ALL moving parts of the door 9 Install the Entrapment Warning...

Page 8: ...ion bar until pilot holes align with bracket Securely tighten collar screws to the torsion bar to 12 14 ft lbs of torque Figure 1 7 Securely tighten both set screws Figure 1 NOTE You may need to manually raise the door slightly in order to reach the set screws 8 Secure the mounting bracket to the wall and to the garage door opener Use the 14 10x1 7 8 inch screws to secure the mounting bracket to t...

Page 9: ... and attach lock template to track 3 Drill holes as marked on the template 4 Fasten power door lock to the outside of the garage door track with hardware provided 5 Run bell wire up wall to garage door opener Use insulated staples to secure wire in several places Insert wire through the bottom of the garage door opener 6 Plug the connector into the garage door opener Installation The power door lo...

Page 10: ... and the 8 hex screws 2 provided in the hardware bag 3 Attach the cable tension monitor to the wall using the hardware provided Make sure that the roller is on top of the cable 4 Run bell wire to garage door opener Use insulated staples to secure wire 5 Connect bell wire to the green quick connect terminals on the garage door opener polarity is not important NOTE Cable must have tension through en...

Page 11: ... or pre wired installations Do not pierce the wire with the staple as this may cause a short or an open circuit 10 Strip 7 16 11 mm of insulation from the end of the wire near the garage door opener Connect bell wire to the quick connect terminals on the garage door opener white to white and white red to red 11 Fasten the warning placard to the wall next to the door control NOTE DO NOT connect the...

Page 12: ...end of the lens over the hinge and pressing up on the other end to latch into place 7 Plug in the light to outlet NOTE Light will not operate until the garage door opener is activated Install Remote Light 6 Installation To prevent possible OVERHEATING of the endpanel or light socket DO NOT use short neck or specialty light bulbs DO NOT use halogen bulbs Use ONLY incandescent DO NOT use bulbs large...

Page 13: ...igned to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as the wall framing Extension brackets see accessories are available if needed If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if reposi...

Page 14: ...g the door Be sure there is enough clearance for the sensor beam to be unobstructed 2 If additional depth is needed an extension bracket see Accessories or wood blocks can be used 3 Use bracket mounting holes as a template to locate and drill 2 3 16 diameter pilot holes on the wall at each side of the door no higher than 6 15 cm above the floor 4 Attach brackets to wall with lag screws not provided...

Page 15: ...black wires into the grey terminal on the garage door opener To insert or remove the wires from the terminal push in the tab with a screwdriver tip 7 16 11 mm HARDWARE WHT BLK Bell wire WHT MOUNTING THE SAFETY REVERSING SENSORS 1 Slide a 1 4 20x1 2 carriage bolt head into the slot on each sensor 2 Use wing nuts to fasten safety reversing sensors to brackets with lenses pointing toward each other a...

Page 16: ...er To avoid installation difficulties do not run the garage door opener at this time To reduce the risk of electric shock your garage door opener has a grounding type plug with a third grounding pin This plug will only fit into a grounding type outlet If the plug doesn t fit into the outlet you have contact a qualified electrician to install the proper outlet There are two options for connecting powe...

Page 17: ...ucted or misaligned while the door is closing the door will reverse and the garage door opener lights will flash ten times If the door is already open it will not close The sensors can be aligned by loosening the wing nuts aligning the sensors and tightening the wing nuts 1 Check to make sure the LEDs in both sensors are glowing steadily The LEDs in both sensors will glow steadily if they are align...

Page 18: ... opener 2 Position the Battery Backup on a structural support ceiling joist or wall stud 3 Attach the Battery Backup to the support with the 1 1 2 inch lag screws 2 provided There are mounting holes on either side of the Battery Backup 4 Connect the Battery Backup cord into the connector on the bottom of the garage door opener 5 Follow all instructions included with the Battery Backup to test for ...

Page 19: ...reaches the desired DOWN closed position 6 Once the door is closed if there appears to be too much pressure on the door you may toggle the door back and forth using the black and yellow buttons to reach the desired closed position 7 Push the door control or programmed remote control This sets the DOWN close limit and the door should open Proceed to Set the Force Travel limits regulate the points a...

Page 20: ...annot open and close the door fully inspect the door to ensure that it is balanced properly and is not sticking or binding If the door is not stopping exactly where you would like it repeat Program the Travel Limits Set the Force Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door NEVER learn forces o...

Page 21: ...rotector System 1 Press the remote control push button to open the door 2 Place the opener carton in the path of the door 3 Press the remote control push button to close the door The door will not move more than an inch and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misal...

Page 22: ... door to the garage door opener pull the emergency release handle straight down a second time until a click noise is heard from the garage door opener The door will reconnect on the next UP or DOWN operation Test the emergency release 1 Make sure the garage door is closed 2 Pull the emergency release handle The garage door should then be able to be opened manually 3 Return the door to the closed p...

Page 23: ...n programmed to the MyQ Internet Gateway you can monitor and control your garage door from any internet enabled computer or smartphone You may program up to 12 Security 2 0 remote controls 2 Security 2 0 keyless entries and a combination of 16 MyQ accessories to the MyQ control panel The garage door opener can be activated through a wall mounted door control remote control wireless keyless entry o...

Page 24: ...Door Control MyQ Control Panel NOTE Due to power consumption this door control Model 888LG cannot be used in conjunction with another wired door control connected to your garage door opener If an additional door control is needed the wireless door control model 41A7773 1 can be programmed to the door control Model 888LG To program the 41A7773 1 to the MyQ Control Panel follow the remote control pr...

Page 25: ...s control systems NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this transceiver are prohibited THERE ARE NO USER SERVICEABLE PARTS Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules and IC RSS 210 Operation ...

Page 26: ...e on the keyless entry keypad Then press the ENTER button 3 The garage door opener lights will flash or two clicks will be heard when the code has been programmed KEYLESS ENTRY LEARN Button LEARN Button Model 825LM Remote Light Control Light module can be synchronized with the garage door opener light bulbs Model 823LM Remote Light Switch Light module can be synchronized with the garage door opene...

Page 27: ...l The red learn LED will turn on 4 The red learn LED will turn off when programming is complete Once the control panel is learned it will appear on your screen You can then name the device e g My Control Panel etc Model 828LG MyQ Internet Gateway www myliftmaster com To Erase All Codes From the Door Control MyQ Control Panel Memory Erase all remote controls and keyless entries 1 Press and hold the...

Page 28: ...and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN then press and hold the button Release the button 2 Press the temporary 4 digit PIN you have chosen then press ENTER 3 To set the number of hours this temporary PIN will work press the number of hours up t...

Page 29: ...disassemble heat above 212 F 100 C or incinerate NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Operation is subject to the following two condition...

Page 30: ...eiving eye sensor clean lens and secure brackets Verify door track is firmly secured to wall and does not move SYMPTOM Door travels 2 3 inches and stops Reprogram limits and forces See Adjustment section If the motor unit continues to travel 2 3 inches check the travel module connection or replace the travel module SYMPTOM No movement motor runs 2 3 seconds Reconnect the emergency release Motor may...

Page 31: ...l My remote control will not activate the garage door Verify the lock feature is not activated on the door control Reprogram the remote control If the remote control will still not activate the door check the diagnostic codes to ensure the garage door opener is working properly The remote control has short range Change the location of the remote control in your car Check to be sure the antenna on ...

Page 32: ...ings may be broken See above If the problem occurs on the first operation of the garage door opener door may be locked Disable the power door lock The garage door opener won t operate due to power failure Manually open the power door lock Use the emergency release handle to disconnect the door The door can be opened and closed manually When power is restored pull manual release a second time If a B...

Page 33: ... 41A6104 Cable tension monitor 8 41C0902 Mounting bracket 9 41A5034 Safety sensor kit receiving and sending eyes with 2 conductor bell wire attached KEY PART NO NO DESCRIPTION 10 41A6388 Collar with set screws 2 11 41A6102 Power door lock 12 41A5266 3 Safety sensor brackets 2 13 380LM Remote Light garage door opener light 14 41D96 1 Light lens for light NOT SHOWN 101D173 Push bar for door control ...

Page 34: ... Assembly Parts 3 2 5 4 1 6 KEY PART NO NO DESCRIPTION 1 041DJ002 Logic board complete with plate 2 41A6408 Travel Module 3 41C168 Transformer KEY PART NO NO DESCRIPTION 4 41A6095 Motor with bracket 5 41B122 Power cord 6 41A6348 3 Cover ...

Page 35: ...Remote Light Switch Automatically control your lights using your garage door opener a SECURITY 2 0 remote control or a MyQ Internet Gateway Simply replaces your current wired wall switch 3 Button Remote Control Includes visor clip MyQ Internet Gateway Internet enabled accessory which connects to the computer and allows you to monitor and control garage door openers and lighting accessories enabled...

Page 36: ...f the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory ...

Reviews: