17
Connect Power
8
Installation
OPTION B: PERMANENT WIRING
CONNECTION
If permanent wiring is required by
your local code, refer to the following
procedure.
To make a permanent connection through
the 7/8 inch hole in the back of the garage
door opener (according to local code):
1.
Be sure power is NOT connected to
the opener, and disconnect power to
circuit.
2.
Remove the garage door opener from
the torsion bar, remove cover screws
and set the cover aside.
3.
Cut the line cord 6" (15.2 cm) above
the strain relief.
4.
Squeeze the strain relief and push
into motor unit, then remove the
strain relief from the line cord.
5.
Install a 90° conduit (not provided)
or fl ex cable adapter (not provided)
to the 7/8" hole. Reinstall garage door
opener to torsion bar.
6.
Run wires through conduit, cut to
proper length and strip installation.
7.
Strip 1/2" (1.3 cm) of insulation from
the existing black, white and green
wires.
8.
Connect the line to the black wire and
neutral to the white wire with wire
nuts (not provided). Connect ground
wire to the green ground screw.
9.
Properly secure wires under plastic
ties so that they do not come into
contact with moving parts.
10. Reinstall
cover.
To avoid installation diffi culties, do not
run the garage door opener at this time.
To reduce the risk of electric shock, your
garage door opener has a grounding type
plug with a third grounding pin. This plug
will only fi t into a grounding type outlet. If
the plug doesn’t fi t into the outlet you have,
contact a qualifi ed electrician to install the
proper outlet.
There are two options for connecting
power:
OPTION A: TYPICAL WIRING
1.
Plug in the garage door opener into a
grounded outlet.
2.
DO NOT run garage door opener at
this time.
To prevent possible SERIOUS INJURY or DEATH from electrocution or fi re:
• Be sure power is NOT connected to the opener, and disconnect power to circuit
BEFORE removing cover to establish permanent wiring connection.
• Garage door installation and wiring MUST be in compliance with ALL local electrical
and building codes.
• NEVER use an extension cord, 2-wire adapter or change plug in ANY way to make it
fi t outlet. Be sure the opener is grounded.
RIGHT
WRONG
WRONG
RIGHT
Green
Ground
Screw
Ground Wire
Black Wire
Wire Nuts
(Not Provided
White Wire
Flexible
Conduit
90˚
Connector
(Not
Provided)
Green Wire
White Wire
Black Wire
BACK VIEW