Rosa 600 luminaires are DMX-512/RDM compliant and include two five-pin
XLR connectors, one for DMX In and one for DMX Thru.
Use the following standard pinout when preparing DMX cable (Belden
9729 or equivalent) with an XLR connector. The second data pair in the
recommended cable type is not used, but is reserved future service.
DMX-512 Pinout
for five-pin XLR
Pin Use
1
2
3
4
5
Push
1
2
3
4
5
1
Common (shield)
2
Data -
3
Data +
4
not connected
5
not connected
Terminate DMX-512
The last luminaire in the DMX control run must be terminated to prevent
signal reflections. Signal reflections cause noise on the data line resulting in
corrupted data between the control source and the luminaire. This can
result in random flashing of the luminaires on that control run.
To terminate the control run, install a DMX termination plug (RAYN Growing
Systems part number SGE1507) on the DMX Thru connector on the last
luminaire on that run.