Specifications
Environment
CAUTION:
Rosa 600 luminaires are not suitable for use in
spaces with restricted air flow. Enclosing the luminaires will
result in overtemp errors and may cause damage to the
luminaire.
•
For indoor use only.
•
Operates in ambient temperatures of 0°C-40°C (32°F-104°F), and
includes a variable-speed fan.
•
Additional temperature specifications:
-
Maximum recommended ambient operating temperature:
Ta = 40°C (104°F)
-
Maximum anticipated external surface temperature at 40°C
ambient: Tmax = 67°C (153°F)
-
External temperatures after 5 minutes of full- brightness operation
at 25°C (77°F) ambient: 36°C (97°F)
-
External Temperature (steady state achieved) at 25°C (77°F):
67°C (153°F)
•
Operates in relative humidity of 0%-90% non-condensing / non-
corrosive.
Note:
Where dewing is anticipated, please contact RAYN Growing
Systems about heating and ventilation mitigation.
Mounting
The installation location and mounting hardware must support the weight
of the luminaire, all cables, and accessories. See
Each luminaire ships with a yoke bracket that can be bolted to in-place
structures or suspended by C-clamp for mounting on standard schedule
pipework or Unistrut with supporting mounting hardware.
Additionally, two channels are provided on the luminaire enclosure for use
with t-nut style hardware.
Rosa 600 Luminaire
Page 3 of 12