![RAYN Rosa 600 Installation Manual Download Page 5](http://html1.mh-extra.com/html/rayn/rosa-600/rosa-600_installation-manual_790524005.webp)
RAYN Installation Guide
Rosa 600 Luminaire
Electrical
Operates between 100-240 VAC, 50/60 Hz
100 VAC
120 VAC
230 VAC
Quiescent Power
5.28 W / 0.11 A
5.24 W / 0.11 A
4.65 W / 0.12 A
Peak Power
670 W / 6.7 A
670 W / 5.59 A
670 W / 2.91 A
Power Factor
0.97
0.97
0.97
Inrush
n/a
n/a
11.75 A
RMS (100 ms)
Wiring
Power Input
A 120 VAC Rosa 600 luminaire is provided with a 3 m (10 ft) power input
cable with a NEMA 5-15P connector.
A 230 VAC Rosa 600 luminaire is provided with a 3 m (10 ft) power input
cable with bare ends. A suitably instructed person (electrically) or
electrician must install a compatible connector. See
.
Custom pre-fitted connectors are available. Contact RAYN Growing
Systems for ordering details.
Wire Color Code
(International
Standard)
Wire Color Code
(North American
Standard)
Connection Type Terminal
Green/Yellow
Green
Earth/Ground
Blue
White
Neutral
N
Brown
Black
Line (Live)
L
Note:
The Rosa 600 luminaire is a Class 1 (IEC 61140) appliance
and must be operated with suitable protective earthing/grounding.
Rosa 600 Luminaire
Page 5 of 12
RAYN Growing Systems