background image

Installation

13

Install the LED Driver

Tip:

Before You Begin

See the

System Overview

for example systems.

Install the related products including the Lyda lamp head and optional DMX
Adapter prior to installing the LED driver.

CAUTION:

Risk of personal injury and/or product damage. Handle the LED

driver carefully. Do not lift, suspend, or move the driver using the input or
output wires.

1.

Rotate 

clockwise

to disconnect

Rotate 
counter-
clockwise 
to connect

Using M4 (#8) hardware, secure the LED driver to a suitable structure
using the built-in mounting flange. The installation location must be
within 3 m (10 ft) of the desired Lyda lamp head installation location.

2. Connect the lamp cable from the LED driver to the installed Lyda

lamp head. The connection is secured by rotating the locking ring
counterclockwise until finger tight.

3. Connect the control cable (optional use for 1-10 V dimming control).

If using the DMX Adapter, connect the control cable from the DMX Adapter to the input
connector on the LED driver.

If using a third-party 1-10 V controller, connect the 1-10 V Dimming Cable (L-DCBE) to the
connector provided on the LED driver and terminate the bare end wires to the third-party
dimming controller.

Purpose Wire Color

Notes

Dim +

violet

1 to 10 V

Dim -

gray

0 V Return

Unused

black/white

This wire is not used for third-party 1-10 V controller purposes

4. Connect the LED driver to the power source. If using a connectorized power input cable,

simply plug the unit into the distributed power input receptacle. If using a bare end power
input cable, terminate the wiring according to the cable type and local codes.

Model

Type

Color

Power Cable,
US Color Code

ground/earth

green

line

black

neutral

white

Power Cable,
IEC Color
Code

protective
earth

green/yellow

line

brown

neutral

blue

Summary of Contents for Lyda

Page 1: ...Lyda System Lamp Head and LED Driver Installation and User Manual Part Number 7431M1200 Rev A Released 2022 05...

Page 2: ...trademarks both marked and not marked are the property of their respective owners For current and complete compliance and product information view the available documentation at rayngrowingsystems com...

Page 3: ...amp Head 3 System Overview 4 Sample Systems 5 Cabling System 6 DMX Dimming 6 1 10 V Dimming 6 Accessories 7 Specifications 8 Environment 8 Weights and Dimensions 8 Clearance 8 Electrical 9 LED Driver...

Page 4: ...yda Lamp Head 11 Install the LED Driver 13 Install the DMX Adapter 14 Power Up Procedure 15 Operation 15 Maintenance and Serviceability 16 Troubleshooting 16 LED Driver 16 Lyda Lamp Head 16 Install Le...

Page 5: ...nd is suitable for mains power input in the range of 100 277 VAC 50 60 Hz It is dimmable using a 1 10 V input or by using an optional DMX Adapter that is also powered by the LED driver The lamp head o...

Page 6: ...iceable Do not disassemble the driver in any way Independent lighting control gear Appareil de contr le d clairage ind pendant Safety extra low voltage device Dispositif de s curit tr s basse tension...

Page 7: ...p head is not user replaceable and must be replaced only by a qualified technician Contact your RAYN Growing Systems provider for assistance Do not stare at the operating light source Ne pas regarder...

Page 8: ...on both ends when installed 3 Lamp Cable Input Attach the lamp cable from the LED Driver to the lamp head input receptacle Rotate the locking ring counter clockwise to connect the Lamp Cable to the la...

Page 9: ...s DMX Termination on the last device Control Cable Lyda Lamp Head Power Cable Line black or brown Neutral white or blue Ground green or green yellow Lamp Cable Control Cable Lyda Lamp Head DMX Adapter...

Page 10: ...d so they are not subject to strain or damage DMX Dimming When utilizing the DMX Adapter to control the lamp head by a DMX control source connect the control cable provided on the DMX Adapter to the L...

Page 11: ...US NEMA 5 15P 1 8 m 6 ft length L PCBEUS W6691 Power Cable Bare Ends US Color Code 1 8 m 6 ft length L PCBEIEC W6692 Power Cable Bare Ends IEC Color Code 1 8 m 6 ft length L LNM 7431K1002 Lens Medium...

Page 12: ...is 85 C 185 F 5 100 condensing non corrosive suitable for damp locations Weights and Dimensions Product Weight Dimensions Notes kg lb mm in Lyda lamp head 2 3 5 1027x104x75 40 4x4x3 Installs suspended...

Page 13: ...er Factor 0 99 0 98 0 95 Input AC Current 2 54 A 1 34 A 1 02 A Inrush Current I2 t 4 39 A2 s Standby Power 0 5 W max Typical Efficiency 89 5 92 5 93 The LED driver is a UL Class I apparatus This equip...

Page 14: ...mp head features 120 beam angle as standard no lens installed A 60 medium beam spread lens is available for field installation and a 120 flat lens is available in cases where additional protection is...

Page 15: ...et suivez les proc dures de Consignation D consignation prescrites par la norme NFPA 70E ou aux r glementations locales applicables Note For North American installation lamp head and LED Driver power...

Page 16: ...For effective convection cooling and to prevent overheating do not install the lamp head vertically on its end Y X 3 If the LED driver has been previously installed connect the lamp cable from the dri...

Page 17: ...ounterclockwise until finger tight 3 Connect the control cable optional use for 1 10 V dimming control If using the DMX Adapter connect the control cable from the DMX Adapter to the input connector on...

Page 18: ...socket style connector Make the connections accordingly See Lyda System with DMX Dimming on page 5 for example system topology Contact your RAYN Growing Systems provider for additional system design...

Page 19: ...evel signaled by the controller Set the appropriate control level on the controller and verify the respective light output WARNING Do not use this fixture with a damaged power cable cord set If the ca...

Page 20: ...lable at rayngrowingsystems com contact Troubleshooting LED Driver To prevent damage to the LED driver an internal sensor monitors the temperature of the driver and decreases the output current as nee...

Page 21: ...u will need to remove the end cap for this procedure Do not attempt this accessory installation with the lamp head suspended It is best accomplished on a flat work surface with all power and cables di...

Page 22: ...18 Lamp Head and LED Driver Installation and User Manual...

Page 23: ...Install Lens 19...

Page 24: ...RAYN Growing Systems LLC All Rights Reserved Trademark and patent info rayngrowingsystems com ip All product information and specifications subject to change RAYN Growing Systems intends this documen...

Reviews: