40
SmartPilot Series Commissioning Guide
Accessing the Calibration modes
You can only access Calibration mode from Standby mode:
1. With the SmartPilot in Standby mode, press and hold the
standby
key for 2
seconds. The display will change to show
DISPLAY CAL
.
2. Press the
disp
key to scroll through the 4 calibration groupings:
• Display Calibration (
DISPLAY CAL
)
• User Calibration (
USER CAL
)
• Seatrial Calibration (
SEATRIAL CAL
)
• Dealer Calibration (
DEALER CAL
)
Note:
You can go backwards through the groups by pressing and holding the
disp
key for
one second.
3. When you reach the Calibration group you want to access, press
auto
to
enter that group:
To prevent accidental access, we have made entry to Dealer Calibration more
+
+
Accessing
Calibration Modes
2 seconds
2 seconds
(saves changes)
Calibration
Modes
to enter seatrial
calibration mode
D6407-2
to enter dealer
calibration mode
to enter display
calibration mode
to enter user
calibration mode
CAL ?
(ST8001 & ST8002 only)
81273_1.book Page 40 Thursday, November 10, 2005 8:25 AM