Chapter 2: SmartPilot Commissioning
23
Enter Dealer Calibration mode
As improper use of the Dealer Calibration settings can seriously impair SmartPilot
performance, we have made entry to the Dealer Calibration mode more difficult.
Ensure you follow the instructions in this step carefully.
1. Start with the SmartPilot in
STANDBY
mode.
2. Enter
DEALER CAL
as follows:
Note:
For more information on SmartPilot settings, refer to Chapter 3:
Set the vessel type
When you select a vessel type, the SmartPilot automatically selects appropriate
default values for various other calibration settings.
Some of these settings will be checked later in this procedure and the remained
should not require any adjustment. The default values for each vessel type are
listed on
page 57
.
ST6001/ST6002 Controllers
ST7001 /ST7002 and ST8001/ST8002
Controllers
• press and hold the
standby
key for two
seconds to enter the Calibration mode
• when the screen shows
DISPLAY CAL
,
press the
disp
key until you see the
DEALER CAL
screen
• press the
auto
key: the display will
change to
CAL?
• press
-1
and
+1
together to enter Dealer
Calibration mode
• press and hold the
standby
key for two
seconds to enter the Calibration mode
• when the screen shows
DISPLAY CAL
,
press the
disp, up or down arrow
key
until you see the
DEALER CAL
screen
• press the
auto
key: the display will
change to
CAL?
• press
-1
and
+1
together (ST7001/
ST7002) or press
up and down arrow
keys
together (ST8001/ST8002)
to enter Dealer Calibration mode
At the CAL ? screen, press + together to enter DEALER CAL
2 sec
x3
-1
+1
or
D6322-2
(ST8001 & ST8002 only)
+
81273_1.book Page 23 Thursday, November 10, 2005 8:25 AM