22
Power out
The ‘POWER OUT’ port is used to connect the digital radar power
cable to supply the 42 V required, also ensure that the screen port is
used.
The VCM100 has status LED’s fitted (
see Table 3-2:, p.43 for
trouble-shooting advice
).
Emergency stop button
The VCM100 unit has an option for an emergency stop button. If
this is used, the factory fitted wire bridge should be removed, and
replaced with the emergency stop button connector wires.
.
CAUTION:
The digital radar has been designed to be used in conjunction
with a VCM100 and is NOT compatible with a direct battery
connection
D10490-1
Ensure either the wire link,
or emergency stop button is fitted