Alarm name Alarm type
Description
Action
Pilot start up
Alarm
Will display
start up for
20 seconds
everytime
the pilot is
powered up
• Self
cancelling.
Waypoint
advance
Alarm
Indicates
change in
waypoint
name or ID
and direction
to turn to new
waypoint.
Initiated in
Track mode.
• Change
pilot
mode.
• Accept
new
waypoint
route.
No Wind
data
Alarm
SmartPilot is
in Wind Vane
Mode but has
not received
Wind Angle
data for 30
seconds.
• Check
wind data
source
and con-
nections.
• Pilot drops
out of
wind vane
mode and
reverts
to auto
mode.
• Change
pilot mode
No speed
data
Alarm
Speed data
has stopped .
• Check
Seatalk
connec-
tions for
short or
open cir-
cuit.
• Check
system for
Seatalk
device
fault.
SeaTalk 1
fail
Alarm
SeaTalk
channel 1
has a com-
munication
problem.
• Change
pilot
mode.
SeaTalk 2
fail
Alarm
SeaTalk
channel 2
has a com-
munication
problem.
• Change
pilot
mode.
Drive short
Warning
Indicates a
short circuit
in the drive
unit
• Pilot will
power
down
• User to
fix short
circuit
Alarm name Alarm type
Description
Action
Clutch short
Warning
Indicates a
short circuit
in the Clutch
• Check
clutch con-
nections at
SPX and
drive unit
• . Check
drive unit
clutch.
• User to
fix short
circuit
Solenoid
short
Warning
Indicates a
short circuit in
the solenoid
• Pilot will
power
down
• User to
fix short
circuit
Pilot controller alarms
79
Summary of Contents for P70
Page 2: ......
Page 4: ......
Page 10: ...10 p70 p70R ...
Page 14: ...14 p70 p70R ...
Page 28: ...28 p70 p70R ...
Page 29: ...Chapter 5 Installation Chapter contents 5 1 Mounting on page 30 Installation 29 ...
Page 38: ...38 p70 p70R ...
Page 48: ...48 p70 p70R ...
Page 58: ...58 p70 p70R ...
Page 68: ...68 p70 p70R ...
Page 74: ...74 p70 p70R ...
Page 80: ...80 p70 p70R ...
Page 94: ...94 p70 p70R ...
Page 110: ...110 p70 p70R ...
Page 118: ...118 p70 p70R ...
Page 121: ......