Alarms menu
Menu item
Description
Options
MOB Data Type
Determines whether Position or Dead Reckoning (DR) data is
displayed. Assuming that your vessel and the MOB are subject to the
same tide and wind effects, the Dead Reckoning setting normally
gives a more accurate course.
• Dead Reckoning
• Position (default)
Alarm Clock
When set to On, an alarm is triggered at the time you specify for the
Alarm Clock Time setting.
Alarm Clock
• Off (default)
• On
Alarm Clock Time
• 00:00 (default)
• 00.01 to 24:00 hrs
Anchor Drift
When set to On, the Anchor Drift alarm is triggered when your vessel
drifts from your anchor position by more than the distance you specify
for the Anchor Drift Range setting.
Anchor Drift
• Off (default)
• On
Anchor Drift Range
• 0.01 — 9.99 nm (or equivalent units)
Countdown Timer
When set to On, counts down the time period you specify for the Timer
Period setting, and triggers an alarm when zero is reached.
Countdown Timer
• Off (default)
• On
Timer Period
• 00h00m (default)
• 00h01m to 99h59m
AIS Targets
When set to On, the alarm for Dangerous Targets is enabled. This
option is only available when an AIS unit is detected. Refer to the AIS
section for details.
Dangerous Targets
• On (default)
• Off
Engine Alarms
When set to On then warning alarms from connected engine
management systems will be displayed on the multifunction display.
Engine Alarms
• On (default)
• Off
Fishfinder Deep
If this option is set to On, an alarm is triggered when the depth
exceeds the value that you specify. This option is only available when
a sonar module is detected.
Note:
The Fishfinder Deep alarm limit cannot be set to a value
less than the Shallow Limit.
Fishfinder Deep
• Off (default)
• On
Deep Limit
• 2 ft (or equivalent units) to the maximum of the
transducer range
Fishfinder Shallow
If this option is set to On, an alarm is triggered when the depth drops
below the value that you specify. This option is only available when a
sonar module is detected.
Note:
The Fishfinder Shallow alarm limit cannot be set to a value
greater than the Deep Limit.
Fishfinder Shallow
• Off (default)
• On
Shallow Limit
• 2 ft (or equivalent units) to the maximum of the
transducer range
Fish
If the Fish alarm and fish depth limits alarm are set to On, a warning
sounds is triggered if any target meets the sensitivity level and is
within the Shallow Fish Limit and Deep Fish Limit that you specify.
The following items are available in the sub-menu:
•
Fish
— Switches fish alarm On and Off.
•
Fish Sensitivity
— If the Fish alarm is set to On, an alarm is
triggered when the fish return strength reaches the sensitivity that
you specify.
•
Fish Depth Limits
— Switches depth limits On and Off.
•
Shallow Fish Limit
— Specifies the lower value for the Fish Alarm
Depth Limit.
Fish
• Off (default)
• On
Fish Sensitivity
• 1 to 10
Fish Depth Limits
• On
• Off (default)
Shallow Fish Limit
118
gS Series
Summary of Contents for gS Series
Page 34: ...102 gS Series...
Page 40: ...120 gS Series...
Page 52: ...138 gS Series...
Page 94: ...180 gS Series...
Page 116: ...202 gS Series...
Page 140: ...226 gS Series...
Page 156: ...242 gS Series...
Page 164: ...264 gS Series...
Page 192: ...326 gS Series...
Page 208: ...www raymarine com...