Note:
For complete connection and installation instructions for
the course computer refer to the documentation that accompanies
the unit.
Cable extensions
You may need to extend the Hydraulic Linear Drive cables.
•
Clutch cable (from hydraulic ram to course computer clutch
connection)
— use minimum 1.5 mm
2
(16 AWG) copper cable.
•
Motor cable (from Hydraulic pump to course computer motor
connection)
— use the following table to determine the correct
cable gauge required:
Drive type
Cable length
Cable gauge
(AWG)
Cable gauge
(mm
2
)
Type 2 (12 V)
Up to 5 m (16 ft)
10
6
Up to 7 m (23 ft)
8
10
Up to 16 m (52 ft)
6
16
Type 2 (24 V)
Up to 3 m (10 ft)
12
4
Up to 5 m (16 ft)
10
6
Up to 10 m (32 ft)
8
10
Up to 16 m (52 ft)
6
16
Type 3 (12 V)
Up to 5 m (16 ft)
8
10
Up to 7 m (23 ft)
6
16
Up to 16 m (52 ft)
4
25
Type 3 (24 V)
Up to 5 m (16 ft)
10
6
Up to 7 m (23 ft)
8
10
Up to 16 m (52 ft)
6
16
Use suitable electrical connectors or junction boxes to connect the
Hydraulic Linear Drive cables to the cable extensions.
Note:
Do NOT untwist the pump cables or remove the
suppression ferrite.
Cables and connections
33
Summary of Contents for E12207
Page 2: ......
Page 4: ......
Page 6: ...6 Hydraulic Linear Drive Installation instructions ...
Page 20: ...20 Hydraulic Linear Drive Installation instructions ...
Page 28: ...28 Hydraulic Linear Drive Installation instructions ...
Page 40: ...40 Hydraulic Linear Drive Installation instructions ...
Page 41: ......
Page 42: ...www raymarine com ...