Example NMEA 0183 device connection using the Actisense® NGW-1
converter
1.
Device NMEA 0183 wires.
2. NMEA 2000 to NMEA 0183 converter (e.g. Actisense® NGW-1 converter,
A80721).
3.
SeaTalkng ™ (female) to DeviceNet (female) adaptor cable (e.g. A06045
or A06075).
4.
SeaTalkng ™ network (requires dedicated 12 V dc power supply).
5. NMEA 0183 wire connections. It is recommended that wire connections
are made using crimps and then insulated using insulation tape.
Converter signal (wire color)
NMEA 0183 device signal
TX/OUT A+ (White)
RX/IN A+
TX/OUT B- (Blue)
RX/IN B-
RX/IN A+ (Red)
TX/OUT A+
RX/IN B- (Black)
TX/OUT B-
Shield/Screen
Vessel Ground
If your NMEA 0183 device has only 3 NMEA 0183 wires, the connection will
differ from that described above. Please see below for alternative wiring:
Connect to receiving device
Converter signal (wire color)
Receiving NMEA 0183 device
signal
TX/OUT A+ (White)
RX/IN
TX/OUT B- (Blue)
NOT CONNECTED
Shield/Screen
Vessel Ground
Connect to transmitting device
Converter signal (wire color)
Transmitting NMEA 0183 device
signal
RX/IN A+ (Red)
TX/OUT
RX/IN B- (Black)
Vessel Ground
Shield/Screen
Vessel Ground
10.3 Network connection
The display can be connected to compatible network products by connecting
a network cable between the product and one of the
NETWORK
connectors
located on the rear of the display. Alternatively, the display can be connected
to a network switch, e.g.: RNS-5, or the YachtSense ™ Link marine router.
1.
Display’s
NETWORK
connector.
46
Summary of Contents for AXIOM 2 XL
Page 2: ......
Page 4: ......
Page 22: ...CHAPTER 5 PRODUCT DIMENSIONS CHAPTER CONTENTS 5 1 Product dimensions page 23 22...
Page 39: ...CHAPTER 9 POWER CONNECTIONS CHAPTER CONTENTS 9 1 Power connection page 40 Power connections 39...
Page 56: ...CHAPTER 13 AUDIO CONNECTIONS CHAPTER CONTENTS 13 1 Audio RCA connections page 57 56...
Page 95: ...RayNet to RJ45 and RJ45 SeaTalkhs adapter cables Spares and accessories 95...
Page 102: ......
Page 107: ......