0049-0867-01X 2
nd
Generation MIU14.4L – USER’S GUIDE 6/22/2011
Rev. A
Page 4 of 39
4. MODEM SPECIFICATION5
The MIU14.4L design is based on Rockwell modem chipsets. Modem control is through the
industry standard 'AT' command set. The MIU14.4L provides all popular error correction and data
compression capabilities. The MIU14.4L provides the following modem features.
Data Command Set
Rockwell AT command set (See Section 11)
Data Modulations and Speeds
Modem
Modulation
Type Sync/Async
Data Rate
(bps)
MIU14.4L V.32bis TCM Async
14400, 1200,
9600, 7200
MIU14.4L V.32 TCM
Async 9600,
4800
MIU14.4L V.33/V.17 TCM Sync
14400, 1200,
9600, 7200
MIU14.4L V.29 QAM Sync
9600, 7200,
4800
MIU14.4L V.27 QAM Sync 4800,
2400
MIU14.4L V.22bis QAM Async 2400,
1200
MIU14.4L V.22 PSK
Async 1200,
600
MIU14.4L
V.21
FSK
Async
0 – 300
MIU14.4L Bell212A PSK Async
1200
MIU14.4L
Bel103J
FSK
Async
0 - 300
Data Modulation Connectivity:
95% or better with Receive Signal Level at –40dBm and Signal/Noise Ratio 20dB (MIU14.4L)
Error Correction and Data Compression:
Error Correction:
MNP Class 2-4, MNP 10, V.42.
Data Compression:
MNP 5, V.42bis.
Serial Formats and Flow Control:
Serial Speeds:
57600, 38400, 19200, 14400, 9600, 4800, 2400, 1200, 300bps
Serial Formats:
8N1, 8E1, 801, 7E1, 7O1, 7N2
Summary of Contents for Telenetics MIU14.4L
Page 20: ...0049 0867 01X 2 nd Generation MIU14 4L USER S GUIDE 6 22 2011 Rev A Page 16 of 39 ...
Page 36: ...0049 0867 01X 2 nd Generation MIU14 4L USER S GUIDE 6 22 2011 Rev A Page 32 of 39 ...
Page 37: ...0049 0867 01X 2 nd Generation MIU14 4L USER S GUIDE 6 22 2011 Rev A Page 33 of 39 ...
Page 38: ...0049 0867 01X 2 nd Generation MIU14 4L USER S GUIDE 6 22 2011 Rev A Page 34 of 39 ...